ABB-Welcome
Pos : 26 /DinA4 - Anl eitungen Onli ne/Ueberschriften/2./Bedi enaktionen @ 20\mod_1323262294281_15.doc x @ 111911 @ 2 @ 1
4.2
Setting
Pos : 27 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Sprec h- und Videover bindung @ 20\mod_1323262368700_15.doc x @ 111927 @ 3 @ 1
4.2.1
Set indoor station address (X200, X100)
Pos : 28 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/83220-AP- xxx/Sprec h- und Videover bindung - 83220- AP- xxx @ 20\mod_1323262341852_15.doc x @ 111919 @ @ 1
Step 1: Hold "light"
Step 2: Hold "talk"
Step 3: Press "mute"
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, 0xx.
LED "unlock" flashes, 1xx.
LED "light" flashes, 2xx;
Step 4: Hold "light"
4.2.2
Set function of light button
Step 1: Hold "light"
Step 2: Hold "unlock"
Step 3: Press "mute"
The value is indicated by LED of each button.(Default value =0)
LED "talk" flashes, switching the lighting.
LED "unlock" flashes, opening the second lock.
LED "light" flashes, room to room intercom.
LED "mute" flashes, call guard unit.
Step 4: Hold "light"
|
button for 3s to enter setting mode. (4 LEDs are on)
button for 3s to enter the setting of X200/X100.
button to change the number.
.
24
button for 3s to enter setting mode (4 LEDs are off)
button for 3s to enter setting mode (4 LEDs are on)
button for 3s to enter the setting of light button.
button to change the function.
button for 3s to enter setting mode (4 LEDs are off)
024
124
224
— 7 —