Operating Instructions
DME4000
Interface
Depending on the sensor type, only the respective interface of the sensor type appears in the menu.
3.1
SSI
For the function of the SSI interface, refer to Chapter 8.2.3 "SSI".
3.1.1
Coding
Binary
Measurement value output in binary code
3.1.2
Mode
25 bit (default)
24 bit + err
24 bit
Plausibility bit:
3.1.3
Activation
On (default)
Off
3.1.4
Monitor
On
Off (default)
3.1
Profibus
3.1.1
Profile
Encoder
SICK (default)
3.1.2
BusAddress
Addr. 006 (default)
Note
For an operation startup example with Siemens Step 7 (see Chapter 9.5 "RS-422 Interface").
8014584/US35/2011-07-07
Menu Structure
SSI
Coding
Mode
Data Format
Binär
Measurement value:
Bit 1 ... 24
LSB: Plausibility bit
Measurement value:
Bit 1 ... 24
LSB: Plausibility bit
Measurement value:
Bit 0 ... 23
1: Plausibility error:
measurement value output 0
Activation
SSI interface in operation, RS 422 interface not in operation.
RS 422 interface in operation, SSI interface not in operation. The RS 422 interface
enables parameterizing the DME with the interface adapter
(1 023 359).
(Set baud rate and protocol under > 3.2 Serial <)
Monitor
Serial monitor interface in connection with the interface adapter (part no.
1 023 359, refer to accessories) via the MF1 and MF2. The switched on monitor
interface is displayed with "Monitor" in the menu 3.3.2 and 3.4.2 MF function. The
SSI interface is capable of performing all functions. Baud rate and protocol are set
via 3.2 Serial.
Multifunctional outputs MF1 and MF2 in operation as set under 3.3/3.4.
PROFIBUS
Profile
This profile corresponds to the standard encoder profile; refer to "9.2 PROFIBUS
Interface".
This profile is based on the standard encoder profile. In addition to the
measurement value, warning, state and error information are transmitted.
For a more precise description, see "9.2 PROFIBUS Interface".
Bus Address
The Profile bus subscriber address is set here.
(001-125)
© SICK AG • Industrial Sensors • Germany • Subject to change without notice
Gray (Default)
Measurement value output in gray code
Gray
Measurement value incl. plausibility bit
coded in gray code
Measurement value:
Bit 1 ... 24
LSB: Plausibility bit (binary)
Measurement value:
Bit 0 ... 23
0: OK
Chapter 3
73