Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 114

FAQ

The answers are listed below in summary form, for further details see the other pages of this document.
1) What do I need to prepare in order to install the boiler-stove?
Flue pipe at least 80 mm in diameter or direct connection to the outside.
An air inlet in the room that is at least 80 cm².
¾" G outlet and inlet fi tting.
¾" G drains connection for overpressure valve.
¾" G load fi tting.
A certifi ed electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the boiler-stove work without water?
NO. Use without water could damage the stove BEYOND REPAIR.
3) Does the boiler-stove generate hot air?
YES. Most of the heat produced is transferred to the water, while heat is released into the room in which the stove is installed by
irradiation and a fan.
4) Can I connect the inlet and outlet of the boiler-stove directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do boiler-stove also supply hot sanitary water?
Hot water can be produced by the use of a special kit, after having assessed the power of the stove in terms of the plumbing sy-
stem.
Evaluate complementary solutions (e.g. solar) for the summer when you do not turn on the stove.
6) Can I discharge the smoke from the boiler-stoves along the wall?
NO, a discharge which is conform with standards (UNI 10683/2012) must reach the ridge of the roof, and in any case proper fun-
ctioning requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke
forms in the installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the boiler-stove for combustion; a direct external connection is also possible.
8) What settings are required on the boiler-stove display?
The desired water temperature. The boiler-stove will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the boiler-stove accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
If an ambient thermostat has been installed, set the temperature of the room.
9) How often do I need to clean the combustion chamber?
Ideally before each time the stove is switched on, when the stove is off and cold. AFTER CLEANING THE EXCHANGER TU-
BES by means of the smoke-channel cleaning handle (see page 51).
10) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the boiler-stove is not used for some time.
11) Can I burn other fuel apart from pellets?
NO. The boiler-stove has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.
12) Can I ignite the boiler-stove by sending an SMS?
Yes, by connecting a dialler to the serial port on the back of the stove using the optional cable
- 55
-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis