Activated charcoal filter (Recirculation version)
• The filter is not washable and cannot be regene-
rated. It must be replaced when led S1 flashes
or at least every 4 months. The alarm signal
will only light up when the extractor motor is
switched on.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
• Remove the grease filters.
• Remove the saturated activated charcoal filters
as shown (A).
• Fit new filters (B).
• Replace the grease filters.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or at a
later date.
• Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power sup-
ply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
LED flashes twice - Activated charcoal filter saturation alarm ENABLED
LED flashes once - Activated charcoal filter saturation alarm DISABLED
50 W halogen light.
• Remove the 2 screws fixing the light cover.
• Remove the lamp by gripping the protruding
part and turning to the left.
• Replace with a new lamp with the same cha-
racteristics, making sure that you insert the two
pins properly into their housings.
• Replace the cover and fix it in position using
the two screws removed as above
GB
REPLaCING THE aCTIVaTED CHaRCOaL FILTER
Lighting
LIGHT REPLaCEMENT
�
�
18