Before installing the KESSEL lifting sta-
tion Aqualift S all parts must be checked
for transport damage.

2.1 Installation in the ground plate

The pump tank must be aligned horizontal-
ly. If necessary, attach inlets at the side.
For this purpose, the flat surfaces of the
tank, if appropriate the adapter and upper
cover section (max. DN 50), must be pre-
scored using the KESSEL saw cap (art. no.
50100). Then insert a suitable elastomer
seal into the bore hole and push the inlet
pipe in place (Fig. 1/2).
Fig. 1
Fig. 2
2. Installation
Caution
Do not locate inlets near the level measure-
ment, floating switch, submersible pipe in
order to avoid malfunction.
A conduit must be provided on site for
connection of the electric cables (Fig. 3).
The conduit can be mounted in the cable
duct provided in the adapter or in any other
spot by pre-scoring the tank (Fig. 1/2).
Insert the enclosed profile lip seal into
the adapter groove, grease it and fit the
upper cover section. Thanks to the design
25
of the upper cover section, the KESSEL lif-
ting station Aqualift S can be adapted exac-
tly to the prevailing installation depth. Gro-
und slopes of up to 5° can be compensated.
Alignment of the cover e.g. to tile pattern is
possible (Fig. 4).
Caution
The upper cover section must be shortened
to the necessary size to achieve minimum in-
stallation depth.
Following final alignment, near the cable duct
and where any additional inlets have been
attached (Fig. 5).