Digital Tracking System
Operation Main Menu
Short press to move to next display. Press and hold (5
seconds) to change units or reset data.
1. Turn pressure to lowest setting. Trigger gun to relieve
pressure. Turn prime valve down to DRAIN position.
2. Turn power on. Pressure display appears. Dashes will
not appear unless pressure is less than 200 psi (14 bar,
1,4 MPa).
Change Display Units
Press and hold button for 5 seconds to change pressure
units (psi, bar, MPa) to desired units. Selection of bar or
MPa changes gallons to litres x 10. To change display
units must be in pressure display mode and pressure must
be at zero.
Job Gallons
1. Short press button to move to Job Gallons (or litres x
10).
NOTE: JOB scrolls past, then the number of gallons spra-
yed above 1000 psi (70 bar, 7 MPa) displays.
2. Press and hold to reset to zero.
Lifetime Gallons
1. Short press button to move to Lifetime Gallons (or litres
x 10).
NOTE: LIFE scrolls briefly, then the number of gallons
sprayed above 1000 psi (70 bar, 7 MPa) displays.
Secondary Menu - Stored Data
1. Perform Pressure Relief, steps 1 - 4 if they have not
already been done.
2. Turn power switch on while holding button down.
3. SERIAL NUMBER scrolls past and then serial number
(e.g. 00001) displays.
165