5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, giving
consideration to sensor reach and mounting
height (Fig� 5�1).
Mounting procedure
(Based on the example of L 220 LED)
• Switch OFF power supply (Fig� 4�1).
• Detach light housing from the wall mount, paying
attention to the position of the sensor (Fig� 5�2).
• Mark drill holes (Fig� 5�3).
• Drill holes and insert wall plugs (concealed power
supply cable (Fig� 5�4).
• Drill holes and insert wall plugs (with spacers for
surface power supply cable (Fig� 5�5).
• Connect conductors (Fig� 5�6).
• Connect plug-in connectors (Fig� 5�7).
• Fit light enclosure (A) onto wall mount (C). Pay
attention to plug-in connections as well as the
position of the sensor (Fig� 5�8).
• Screw light enclosure into place (Fig� 5�9).
• Switch ON power supply (Fig� 5�10).
• Make settings ➔ "6� Functions".
6� Functions
The sensor-switched light can be put into service
after mounting the light enclosure and connecting
to the mains power supply.
Factory settings:
Twilight setting:
Daylight operation 2000 lux
Time setting: 8 s
Twilight setting / response threshold (Fig� 6�1)
– The sensor's response threshold can be infinitely
varied from 2–2000 lux.
– Control dial set to
= daylight operation,
approx. 2000 lux.
– Control dial set to
= night-time operation,
approx. 2 lux.
Time setting (Fig� 6�1)
– Light ON duration can be infinitely varied from
8 s - 35 min
– It is recommended that the shortest time be
selected for setting the detection zone.
– Control dial, shortest time = approx. 8 s
– Control dial, longest time = approx. 35 min
Adjusting the detection zone / reach setting
– Depending on the mounting height, the detection
zone setting can be optimised to suit require-
ments. The shroud foil can be used for masking
out any number of lens segments to limit reach
as required, e.g. to mask out paths or neigh-
bouring property (Fig� 6�2).
– Reach can be adjusted from 2-10 m by tilting
the sensor (D) through 90° (Fig� 6�3)�
7� Functional warranty
This Steinel product has been manufactured with
utmost care, tested for proper operation and safety
and then subjected to random sample inspection.
Steinel guarantees that it is in perfect condition
and proper working order. The warranty period is
36 months and starts on the date of sale to the
consumer. We will remedy defects caused by
material flaws or manufacturing faults. The warran-
ty will be met by repair or replacement of defective
parts at our own discretion. The warranty shall not
cover damage to wear parts, damage or defects
caused by improper treatment or maintenance.
Further consequential damage to other objects
shall be excluded.
Claims under the warranty will only be accepted
if the unit is sent fully assembled and well-packed
with a brief description of the fault, a receipt or
invoice (date of purchase and dealer's stamp) to
the appropriate Service Centre.
Repair service:
If defects occur outside the
warranty period or are not
covered by the warranty, ask
your nearest service station for
the possibility of repair.
– 10 –
8� Technical specifications
Dimensions (W × H × D)
L 240/L 244 LED 165 × 305 × 81
L 220/L 224 LED 246 × 251 × 84
Voltage supply
220-240 V, 50 / 60 Hz
Output
L 220 7.5 W 550 lm 73.3 lm/W
L 224 7.5 W 410 lm 54.7 lm/W
L 240 7.5 W 570 lm 76.0 lm/W
L 244 7.5 W 500 lm 66.7 lm/W
Colour temperature
3000 K (warm white), SDCM 3
Colour rendering index
Ra ≥ 80
LED life expectancy
50,000 h (L70B10 to LM80)
Sensor technology
Passive infrared
Angle of coverage
180°
Reach
max. 10 m
Time setting
8 s - 35 min
Twilight setting
2-2000 lux
IP rating
IP 44
Protection class
II
Impact resistance
IK 07
Temperature range
-20° to +50°C
9� Troubleshooting
Malfunction
Cause
Sensor-switched light
■ Fuse faulty, not switched ON,
without power
break in wiring
Sensor-switched light
■ Surroundings still too bright
will not switch ON
■ Mains switch OFF
■ Fuse blown
■ Detection zone not correctly
adjusted
Sensor-switched light
■ Continued movement within
will not switch OFF
the detection zone
Sensor-switched light
■ Cars in the street are detected,
switching ON when it
for example
should not
Changing reach
■ Differing ambient temperatures
Remedy
■ Fit new fuse, turn ON mains
switch, check wiring with voltage
tester
■ Wait until response threshold is
reached or adjust setting
■ Switch ON
■ Fit new fuse, check connection
if necessary
■ Readjust
■ Check detection zone and
readjust if necessary
■ Check detection zone and
readjust if necessary
■ When it is cold, shorten reach
by tilting sensor down,
move it up in warm weather
– 11 –