8� Technische Daten
Abmessungen (B/H/T)
L 240/L 244 LED 165 × 305 × 81
L 220/L 224 LED 246 × 251 × 84
Netzanschluss
220-240 V, 50/60 Hz
Leistung
L 220 7,5 W 550 lm 73,3 lm/W
L 224 7,5 W 410 lm 54,7 lm/W
L 240 7,5 W 570 lm 76,0 lm/W
L 244 7,5 W 500 lm 66,7 lm/W
Lichtfarbe
3000 K (warmweiß), SDCM 3
Farbewiedergabeindex
Ra ≥ 80
LED Lebensdauer
50.000 h (L70B10 nach LM80)
Sensortechnik
Passiv-Infrarot
Erfassungswinkel
180°
Reichweite
max. 10 m
Zeiteinstellung
8 s - 35 min
Dämmerungseinstellung
2-2000 Lux
Schutzart
IP 44
Schutzklasse
II
Schlagfestigkeit
IK 07
Temperaturbereich
-20 bis +50 °C
9� Betriebsstörungen
Störung
Ursache
SensorLeuchte
■ Sicherung defekt, nicht einge-
ohne Spannung
schaltet, Leitung unterbrochen
SensorLeuchte
■ Umgebung noch zu hell
schaltet nicht ein
■ Netzschalter AUS
■ Sicherung defekt
■ Erfassungsbereich nicht gezielt
eingestellt
SensorLeuchte
■ dauernde Bewegung im
schaltet nicht aus
Erfassungsbereich
SensorLeuchte
■ Erfassung von z.B. Autos auf der
schaltet unerwünscht ein
Straße
Reichweitenänderung
■ andere Umgebungstemperaturen
Abhilfe
■ neue Sicherung, Netzschalter
einschalten; Leitung mit
Spannungsprüfer überprüfen
■ warten bis Ansprechschwelle er-
reicht ist oder Wert neu einstellen
■ Einschalten
■ neue Sicherung, evtl. Anschluss
überprüfen
■ neu justieren
■ Bereich kontrollieren und
evtl. neu justieren
■ Bereich kontrollieren und
evtl. neu justieren
■ bei Kälte Sensorreichweite
durch Abschwenken verkürzen,
bei Wärme höher stellen
– 8 –
GB
1� About this document
Please read carefully and keep in a safe place�
– Under copyright. Reproduction either in whole or
in part only with our consent.
– Subject to change in the interest of technical
progress.
Symbols
!
Hazard warning!
Reference to other information in the
...
document�
2� General safety precautions
Disconnect the power supply before
!
attempting any work on the unit�
• During installation, the electric power cable to be
connected must not be live. Therefore, switch off
the power first and use a voltage tester to make
sure the wiring is off-circuit.
• Installing these lights involves work on the mains
voltage supply; installation must therefore be car-
ried out professionally in accordance with the ap-
plicable national wiring regulations and electrical
operating conditions (
-VDE 0100,
-ÖVE/
D
a
ÖNORM E 8001-1,
-SEV 1000)
h
• Only use genuine replacement parts.
• Repairs may only be made by specialist work-
shops.
3� L 220 LED / L 224 LED
L 240 LED / L 244 LED
Proper use
– Sensor-switched outdoor light with LEDs as
the light source.
– Suitable for wall mounting outdoors.
The L 220 / L224 LED and L 240 / 244 LED
sensor-switched outdoor lights, referred to in the
following as lights, are active motion detectors.
Movement activates light. For your convenience,
safety and peace of mind. The integrated pyroelec-
tric infrared detector senses the invisible heat radi-
ated from moving objects (people, animals, etc.).
The heat detected in this way is converted
electronically into a signal that switches the light
on. Heat is not detected through obstacles, such
as walls or panes of glass, and will therefore not
activate the light.
Package contents L 240 LED / L 244 LED (Fig� 3�1)
Package contents L 220 LED / L 224 LED (Fig� 3�2)
Product dimensions L 240 LED / L 244 LED (Fig� 3�3)
Product dimensions L 220 LED / L 224 LED (Fig� 3�4)
Product components
L 240 LED / L 244 LED (Fig� 3�5)
L 220 LED / L 224 LED (Fig� 3�6)
A
Light enclosure with base
B
Plug-in terminal
C
Wall mount
D
Sensor
4� Installation
• Switch OFF power supply (Fig� 4�1)
The leads consist of three wires:
L
= phase conductor (usually black,
brown or grey)
= neutral conductor (usually blue)
N
PE = protective-earth conductor (green/yellow)
If you are in any doubt, identify the conductors
using a voltage tester; then disconnect from the
power supply again. Connect the phase conductor
(L) and neutral conductor (N) to the terminal block.
Important:
Incorrectly wired connections will produce a short
circuit later on in the product or your fuse box. In
this case, you must identify the individual conduc-
tors once again and re-connect them. A mains
power switch for turning the unit ON and OFF may
of course be installed in the mains supply lead.
Note:
The light source in this light must only replaced by
the manufacturer or a service engineer authorised
by the manufacturer or by a similarly qualified
person.
Connect the mains power supply lead (Fig� 5�6)
Wiring diagram (Fig� 4�2)