Herunterladen Diese Seite drucken

Gude 400/10/50 N Bedienungsanleitung Seite 15

Vorschau ausblenden Andere Handbücher für 400/10/50 N:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
(The condensed fluid may be brown-coloured due to
surface layer from the air jet)
1.
Pull the connector plug out of socket!
2.
At low pressure in the air jet open the bleeder (9)
(max. of 1 bar) and completely empty the condensed
fluid (use a suitable container)
3.
Close the valve.
Air filter
Sometimes it is necessary to clean the filter bed. For that
purpose remove the air filter cover screw and remove the
foam filter. Wash it in warm soap water solution. Let the
Service
Any technical questions? Complaint? Do you need spare parts or operation manual?
Go to our website www.guede.com and the section Service will help you quickly and without bureaucracy. Please, help us to help you.
In order to identify your device in case of complaint, please indicate serial number, order number and year of manufacture. All
information is available on the product label. To have all information always at hand, put them down.
Serial number:
Order number:
Year of manufacture:
Phone:
+49 (0) 79 04 / 700-360
Fax:
+49 (0) 79 04 / 700-51999
E-Mail:
support@ts.guede.com
Important information for the customer
Please be sure to know that returning the product in or after the warranty period must be made in the original packaging.
foam filter dry and reinsert it to its place. Now assemble the air
filter cover again.
Fuse against overheating: (depending on model)
If the compressor is loaded by a technical defect or possibly also
by continuing operation, the power feed will be automatically
interrupted by a thermo-switch. If such situation occurs it is
advisable to disconnect the compressor from the mains and let it
cooled down for approx. 5 minutes. If the compressor does not
start after certain period of operation, let it cooled down for
additional 3 minutes.

Werbung

loading