MCS T6, MCS T12, MCS T16
6
Operating elements
6.1
Control Panel
Key to fig. 1, page 3:
Item
Name
1
Power Button
2
Fan
Button
3
Down Button
4
Faceplate sensor The faceplate sensor will read the room temperature unless a
5
Up Button
6
Display
7
LED "Heat
Mode"
8
LED "Fan
Indicator"
9
LED "Cool
Mode"
EN
Description
Press and release to toggle between the On and Off Modes.
Press to advance through the available fan settings. "1"(lowest)
through "6" (highest) indicates Manual Fan Speeds.
The letter "a" indicates automatic fan operation selected.
Press and release to display the set point.
Press and hold the Down Button to decrease the set point. Set
point is decreased 0.5 °C or 1 °F each time the button is
depressed.
remote air sensor is installed.
Press and release to display the set point.
Press and hold the Up Button to increase the set point. Set
point is increased 0.5 °C or 1 °F each time the button is
depressed.
The inside air temperature is displayed when the control is on.
The set point is displayed when either Up or Down Button is
pressed.
The display also indicates program information and fault
codes.
When the control resumes operation after a power interruption
all the display LEDs will turn on for one second. This is normal
operating condition and is referred to as Power On Reset.
This LED is lit when
– the Heat Only Mode is selected
– or the unit is in a heating cycle.
This LED is lit when a Manual Fan Speed is selected.
This LED is lit when
– the Cool Only Mode is selected
– or when the unit is in a cooling cycle.
Operating elements