The DBX-68 is capable of registering up to 4 baby units. This way you
can monitor 4 babies and because you can assign an individual name to
each unit, you can directly determine which child is crying. Additionally,
for each baby unit you can set the talk-back function, feeding timer, room
temperature, lullabies and night light.
6.1 TO REGISTER & ASSIGN A NAME:
Attention: only during registration a name can be assigned to the
baby unit. If the baby unit is already registered and you only need
to adjust or set the name, you'll only be able to this this by following the
registration process again.
When you're only expanding your setup, ALL baby units must be registered
(again), i.e. also the baby units that were previously registered. However,
the names of baby units previously registered will remain in the memory.
preparation:
1. switch off the parent unit and the/all baby unit(s) by briefly pressing and
holding the
button until the display is completely empty
parent unit:
2. press and hold the TALK button on the rear of the parent unit
3. now press and hold the
button for approximately 3 seconds until the
parent unit turns on and P/PAIRING appears in the display with the P
flashing. Now release both buttons
first baby unit:
4. press and hold the
button until first the parent unit switches on after
approx. 3 seconds and then 'P' starts flashing in the display after
another 2 seconds or more, now release the
5. use the
and
buttons to select the respective baby unit (select 'baby-
1' for the first baby unit, 'BABY-2' for the second unit, etc.) and press
6. use the
and
buttons to select the first letter of the name and press
the M button
7. repeat this for all of the following letters ('space' is located directly after
the 'ABC', followed by the numbers 1 through 9. The name may consist
of a maximum of 8 characters)
button
46
8. when finished, briefly press the
briefly press the
button again to register the baby unit on the parent
unit
9. now switch off this baby unit (briefly press and hold the
put it aside for the moment
additional baby units:
10. repeat steps 4 through 9 for all additional baby units
switch off:
11. after all baby units are registered according to the procedure above,
finally switch off the parent unit by briefly pressing and holding the
button
12. now switch on the parent unit and baby unit(s) in the usual way, as
described in paragraph 4.2.

6.2 OPERATION WITH MULTIPLE BABY UNITS:

When all babies are sleeping and the baby units
are all set to sleep mode, the parent unit will first
show the status of baby unit 1 (temperature, battery
indication, night light or lullabies are switched in,
etc.), after 15 seconds the status of baby unit 2, then
unit 3 and finally unit 4
This is repeated continuously for as long as all
babies are sleeping (or when quiet)
-
Unregistered baby units will be skipped.
-
When a baby unit is registered, but not in communication with the
parent unit (out of range, empty battery, switched off), the parent
unit will emit a warning signal. Only after the cause for this out-of-
range notification is cleared, will the parent unit switch over to the
next baby unit.
As soon as one of the babies starts crying, the parent unit will instantly
indicate the sound and status of the baby unit where the crying is
coming from. Don't forget that baby unit 1 always has the priority; this
means that when all babies are crying, the parent unit will indicate the
status of baby unit 1. The sequence is: baby-1, baby-2, baby-3, baby-4.