Cleaning

Never direct the water jet
against the washer, nor clean
the washer under flowing water.
This could give rise to the dan-
ger of electric shock and dam-
age the washer!
Always keep the washer clean. Do not
use any detergents or solvents.
Always keep the ventilation slots
clean and free.
Only clean the pressure washer with a
soft brush or a slightly moist cloth.
In case a nozzle of the jet tube (12/13)
is clogged up, use the nozzle cleaning
pin (15) to remove the object from the
nozzle.
G
If necessary, take off the water
connection with the filter insert (8)
and clean the filter insert.

Maintenance

The pressure washer is maintenance free.
Ask our service centre to carry
out any work that is not de-
scribed in these instructions.
Use only original parts.

Storage

Drain all the water from the pressure
washer. Disconnect the unit from the
water supply. Press the On/Off switch
A
(
5) to turn on the pressure washer
for no longer than 1 minute until no
more water escapes from the high-
pressure connection (
the unit.
A
3). Turn off
Protect the pressure washer and its
accessories from frost when they
have not been completely drained of
all water.
Store the pressure washer and its ac-
cessories in a frost-free room.
To transport or put away the equip-
ment, use only the carrying handle.
Store the equipment only in a horizon-
tal position in order to protect it from
any damage.

Technical data

Pressure Washer ..................... HDR 100
Mains connection................230 V~, 50 Hz
Power consumption ...................... 1450 W
Mains cable .........................................5 m
Weight (incl. all parts) ...................... 6.1 kg
Safety class .........................................
Degree of protection .......................... IPX5
Rated/operating pressure (p).......... 7 MPa
Max. permissible pressure (p max) ..10 MPa
Max. inflow pressure (p in max)... 0.8 MPa
Max. inflow temperature (T in max) ...40°C
Pumping rate, water (Q) ................. 5 l/min
Max. pumping rate, water
(Q max) ........................................ 6.6 l/min
Sound pressure level
(L
) ..............76.4 dB(A); K
pA
Sound power level (L
measured ..... 88.8 dB(A); K
guaranteed ...............................95 dB (A)
Vibration (a
) .........0.259 m/s
n
Technical and optical changes can be car-
ried out in the course of further develop-
ment without notice. All dimensions, refer-
ences and information of this instruction
manual are therefore without guarantee.
Legal claims, which are made on the ba-
sis of the instruction manual, cannot thus
be considered as valid.
GB
=3.0 dB(A)
pA
)
WA
=3.0 dB(A)
WA
; K=1.5 m/s
2