Herunterladen Inhalt Inhalt Diese Seite drucken

Leister LQS Geosta G5 Bedienungsanleitung Seite 30

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
1. In this case, the basic functions of device operation are available to the user, allowing them to weld
without data recording.
2. Data recording can be used when these warnings are displayed. In these circumstances, it must be ensu-
red that data cannot be transferred from the device to the LQS app due to the problem.
3. Data recording can be used when these warnings are displayed. It must be ensured that location data is
not held in the data file when GPS is activated.
Take the relevant course of action to resolve the reported warning:
Error code/
warning message
Unknown HMI Version
Date/Time halted
Invalid Date/Time
Memory Full
Memory Card
Access
WLAN Module Access
GPS Module Comm.
4.
If the warning is still displayed, contact the Leister Service Center.
30
Memory Card Access
WLAN Module Access
GPS Module Comm.
Measure
Switch off the device and restart after a few seconds.
Switch off the device and restart after a few seconds.
Set the date and time in the Settings menu under "Welding Data Record." with "Set
Date & Time".
Synchronize data with the LQS app.
Switch off data recording in the menu and restart:
- Release the clamping lever and switch off the drive.
- Set "Data Recording" to 0 in the Settings menu under "Welding Data Record".
- After a few seconds, set "Data Recording" to 1 again and exit the menu.
- Restart the drive. (The heating must also be switched on.)
- The log file is prepared. The warning should no longer be displayed in the status
line (35).
If the warning is still displayed:
- Switch off the drive and heating.
- Switch off device using the main switch.
- Restart the device after a few seconds.
- Restart the heating and drive.
- The log file is prepared. The warning should no longer be displayed in the status
line (35).
4
Switch off the device and restart after a few seconds.
Switch off the device and restart after a few seconds.
A problem with the memory card occurred du-
ring data recording. In this case, welding data is
no longer displayed but the welding continues.
symbol flashes in the status line (35).
The
The following message also appears in the
display. The message can be acknowledged by
briefly pressing the "e-Drive"
There is a problem with the WLAN module.
The GPS module is not sending any data.
4
4
4
4
4
.
2
3

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Lqs geosta g7

Inhaltsverzeichnis