Test your device on program PG02.
f
f
Gradually increase the power.
f
f
You will begin to feel contractions, the device is working.
f
f
VI. IMPORTANT INFORMATION
P lease read this before using the device
1
You have just acquired an effective and powerful professional device.
You must take the time to discover how it works.
1 - Read the instructions carefully
2 - Ensure that the batteries are fully charged prior to use
3 - Test the device on your biceps following the quick test procedure above.
P recautions
2
Hypersensitivity to electro-stimulation may cause a skin reaction in certain individuals.
f
f
Keep out of the reach of children or mentally-impaired persons. This product contains small parts which can be easily
f
f
swallowed.
Only use GlobalStim with the accessories supplied and recommended by SPORT-ELEC® INSTITUT.
f
f
Do not use GlobalStim when driving, operating machinery, or during any activity where electro-stimulation could result in the
f
f
risk of injury to the user.
Always position the belt in accordance with the information provided in this manual.
f
f
Do not apply the electrodes to the lower part of your neck. Muscle contraction may be very strong and cause respiratory
f
f
problems, as well as affect heart rate and blood pressure
Do not apply to the heart area, as electro-stimulation may cause heart rhythm disturbances.
f
f
Do not place electrodes on the face, head or temples. The effects of electro-stimulation on the brain are unknown.
f
f
Only apply the electrodes to clean and healthy skin. Do not carry out electro-stimulation on an open wound or on swollen,
f
f
infected or inflamed areas, or on skin rashes (e.g. phlebitis, thrombophlebitis, varicose veins, etc.)
Do not use in the bath, shower or for any activity in contact with water.
f
f
Do not use when sleeping.
f
f
Do not use if you are fitted with an IUD contraceptive device, as contraceptive efficiency under electro-stimulation has not
f
f
been established.
Do not use on parts of the body other than those for which the accessories have been designed.
f
f
The electrodes are for personal use. For hygiene reasons, they must always be used by the same person.
f
f
Special precautions should be taken in the following circumstances:
Persons with suspected epilepsy
f
f
If you have a tendency to internal bleeding or bleeding following an injury or fracture.
f
f
Following a surgical operation. (Electro-stimulation may disrupt the recovery procedure.)
f
f
In areas of the skin where sensitivity is impaired.
f
f
THERAPEUTIC CLAIMS
Individuals: for the strengthening and/or maintenance of
f
f
muscle strength, to remodel your figure and for pain relief.
Physiotherapists: for the relief of muscular tension and
f
f
within the scope of functional rehabilitation.
Hospital sector: for the prevention of muscular amyotro-
f
f
phy and for the treatment of pain
ADVERSE EFFECTS
Skin irritation.
f
f
Mild burns to the skin where the electrodes are applied.
f
f
14
- USER MANUAL
MEDICAL ADVICE
Seek the advice of your doctor in the following cases:
You suffer from serious back pain.
f
f
You have a serious illness not mentioned in this manual.
f
f
You have recently undergone a surgical procedure.
f
f
You take insulin for diabetes.
f
f
ADVICE FOR LARGER SIZES
If the belt is not long enough for you to attach it around your
waist, use the belt extension provided.
RECOMMENDATIONS FOR USE
You can restart a program cycle on another muscle zone.
f
f
For optimum use, refer to the diagrams shown in this
f
f
manual.
The units can be cleaned using a cloth dampened with a
f
f
disinfectant solution.
If the device is not used for some time, the batteries must
f
f
be recharged.
CONTACT SPORT-ELEC® INSTITUT OR
AN AUTHORIZED DISTRIBUTOR IF:
You experience any irritation, skin reaction, hypersensi-
f
f
tivity or any other reaction. However, please note that
any redness of the skin on contact with the electrodes is
normal and disappears shortly after using your belt.
Correct use of the electro-stimulation belt should not
f
f
cause any discomfort. SPORT-ELEC® INSTITUT declines all
responsibility if the user does not follow the instructions
described in this manual.
If for any reason you are in any doubt concerning the use
f
f
of this device, consult your doctor prior to use.
VII. CLEANING AND MAINTENANCE
U nits:
1
The units can be cleaned with a cloth soaked in a disinfectant solution.
A dhesive electrodes:
2
Rehydrate the adhesive side of the electrodes before and after use. A disinfectant agent can be used. They should be stored on
the original backing sheet in a plastic bag between 5°C and 10°C (for example in a separate compartment in your refrigerator).
VIII. TECHNICAL SPECIFICATIONS
B elt
1
References ......................................................................
Size (unisex) .................................................................... from 34 to 60
Length of the unfolded belt .............................. .................. 126 cm
Extension lead ................................................................. ~35 cm
Fabric ............................................................................ polyester
A dhesive electrodes:
2
Class I medical device (Directive 93/42/CEE)
Adhesive, hydrophilic and hypoallergenic electrodes
References ...................................................................... ELECFREEACTION-S & ELECFREEACTION-L
Contact area ................................................................... 67.5 x 47 mm (x2)
Estimated life expectancy ................................................... 40 uses
Please order new GlobalStim-compatible adhesive electrodes on www.sport-elec.com.
M ains power supply
3
Reference ....................................................................... MN-A403-E120
Input / Output ................................................................. AC 100-240V - 50/60Hz - 0.25A
Only use the power supply provided with the device.
Please replace it in the event of damage (contact SPORT-ELEC® or order online at www.sport-elec.com).
- USER MANUAL
RESTRICTIONS OF USE
The belt must not be connected to another device or any
f
f
other object other than the GlobalStim.
The complete device must be used, with all detachable
f
f
parts in place.
Do not touch the inside of the belt when the device is
f
f
switched on.
Do not use the electro-stimulation belt when driving or
f
f
operating machinery.
Do not use in damp conditions.
f
f
Use the device in a clean environment (dust and dirt-
f
f
free...).
Keep the device away from all sources of heat.
f
f
Keep the device away from any wave-emitting or high
f
f
frequency equipment.
To reposition the electro-stimulation belt during the
f
f
session: stop the program in progress, loosen the belt,
reposition it and restart once the belt has been readjusted.
REPAIRS
If your device is not working correctly, stop using it and
contact your retailer.
DC 5V
600mA
15