5
Technical data
General data/operating conditions
5
Technical data
General data/operating conditions
Field
Order designation
Communication medium
Communication profile
Network topology
Max. number of participants
DeviceNet participant
Baud rate [kbit/s]
Max. possible bus cable length
External voltage supply
Type of protection
Ambient temperature
Climatic conditions
Degree of pollution
X3.1/
V+
External DC voltage supply for the function module:
+24 V DC ±10 %, max. 80 mA
The current flowing via terminal V+ when looping through the supply voltage to other
bus devices must not exceed 3 A.
X3.2/
7
Reference potential 1
39
Reference potential 2 of controller inhibit (CINH) at X3.2/28
28
Controller inhibit
l
Start = HIGH (+12 V ... +30 V)
l
Stop = LOW (0 V ... +3 V)
Input resistance: 3.3 k
20
+ 20 V internally for CINH, reference potential 1, load capacity: I
64
Values
E82ZAFVC010
DIN ISO 11898
DeviceNet
Line terminated at both ends (R = 120 Ohm)
63
Slave
125, 250, 500
depending on the cable used, see ^ 55
see ^ 52
IP20
Operation:
Transport:
Storage:
Class 3K3 according to EN 50178 (without condensation,
average relative humidity 85 %)
EN 50178, pollution degree 2
W
l
PT version
−20 °C ... +60 °C
−25 °C ... +70 °C
−25 °C ... +60 °C
max
EDK82ZAFVC010 DE/EN/FR 2.0
= 30 mA