Type 3232, 3233, 3233 K, 3234,
3235, 3239
Procedure:
→
Cross-loosen fastening screws and remove actuator with dia-
phragm from the housing.
→
Weld or glue housing in the pipeline.
→
After welding or gluing in the housing, smooth the housing surface
(if required) by grinding.
→
Clean the housing carefully.
→
Place actuator on the housing.
→
Lightly cross-tighten the fastening screws until the diaphragm is
between the housing and actuator.
Do not tighten screws yet.
→
Activate the diaphragm valve twice to position the diaphragm
correctly.
→
Tighten the fastening screws up to the permitted tightening
torque (see tables in chapter „8.3.2. Tightening torques for
diaphragms").
Installation
8.3.2. Tightening torques for diaphragms
Orifice
Diaphragm
(Diaphragm size)
EPDM / FKM
DN [mm]
8
15
20
25
32
40
50
Tab. 8:
Tightening torques for diaphragms. Actuator PPS or
stainless steel
Orifice
Diaphragm
(Diaphragm size)
EPDM / FKM
DN [mm]
65
80
100
Tab. 9:
Tightening torques for diaphragms. Actuator stainless steel
english
Actuator PPS or stainless steel
Diaphragm
PTFE/advanced
PTFE/laminated
advanced PTFE
2
2,5
3,5
4
4
4,5
5
6
6
8
8
10
12
15
Actuator stainless steel
Diaphragm
PTFE/advanced
PTFE/laminated
advanced PTFE
20
30
30
40
40
50
17