7.6.1 Timer Setting of Relay Contacts "Aux Out"

You can determine the period until the relay contacts "Aux Out" (i) are triggered yourself (to
which e.g., a motion detector is connected). To do this, enter the following combination, while
you are in the programming mode:
* 58 TTT
In this case TTT stands for 01 to 999 seconds. If it is set to 000, the relay contacts will be active
until the password for the relay contact "Aux Out" (i) is re-entered.

7.6.2 Response Mode of Relay Contacts "Aux Out"

The relay contacts Aux Out" (i) are triggered via the password for the relay contacts "Aux Out"
(i) by default.
However, you can trigger the relay contacts in different ways. To do this, this code lock offers
you comfortable options to determine the response mode.
In order to determine the desired response mode, please enter the following combination while
you are in the programming mode:
* 57 C
In this case C stands for the desired mode.
Modes:
C = 0
No function
C = 1
Enables door surveillance (*)
C = 2
Enables triggering of "Aux Out" (i) relay contacts in the case of incorrect input of user
password or master code
C = 3
Enables triggering of "Aux Out" (i) relay contacts via "*" pushbutton or of the bell
pushbutton (1)
C = 4
Enables triggering of "Aux Out" (i) relay contacts via the sabotage contact (g)
C = 5
Enables an extended door surveillance (**)
C = 6
Enables triggering of "Aux Out" (i) relay contact as soon as the "Lock Out" (h) relay
contacts are activated
C = 7
Enables triggering of "Aux Out" relay contacts via the assigned password (see
chapter 7.6)
22
6.2 Branchement
a) Connexion « 12-24 V AC/DC »
Elle sert à appliquer la tension de service.
b) Sortie d'alarme (-)
Elle sert à raccorder une sirène d'alarme.
c) Connexion « Egress »
Elle sert à raccorder une touche NO pour
déclencher les contacts de relais « Lock
Out » (h).
d) Connexion
« Contact d'ouverture magnétique »
Elle sert à raccorder un contact d'ouverture
magnétique (NC).
e) Cavalier
« Contact d'ouverture magnétique »
Ce cavalier doit être enlevé quand un contact
d'ouverture magnétique est relié à la con-
nexion « Contact d'ouverture magnétique »
(d).
f) Cavalier « Reset »
Il sert à effectuer une réinitialisation des
réglages d'usine.
g) Contact anti-sabotage
Il est déclenché au moment où le couvercle
du boîtier est ouvert.
h) Contacts de relais « Lock Out »
i) Contacts de relais « Aux Out »
a
b
c
d
e
f
g
h
i