23. DETAILS OF DATA INPUT I OUTPUT
2. Instrument Parameter Settings output (B)
B 0,0,0,-30,0,0,0,0,0,0,0,0[,SUM]CRLF
a
b c d e f g h i j k I m
a) Data identifying code
b) Distance measurement units (0: meters, 1: feet)
C) Temperature and Pressure units
(0: "C / hPa, 1: "C / mmHg, 2: "F 1 hPa, 3: "F / mmHg, 4: "F, inchHg)
d) C&R correction (0: None, 1: Applied (K=0.142), 2: Applied (K=0.20))
e) Prism constant 99 to 99(mm)
f)
Angle measurement units (0: degree, 1: gon, 2: mit)
g) Angle resolution 0: 1
",
1:5"
h) Vertical angle display (0: Zenith 0°, 1 : Horizontal O0, 2: Horizontal t90°)
i)
Vertical circle indexing(0: Auto, 1 : Manual)
j)
Tilt angle compensation (0: Yes, 1 : No, 2: Vertical angle only)
k) Horizontal circle indexing (0: Auto, 1 : Manual)
I)
Coordinates format (0: N, E, Z, 1: E, N, 2)
3. Instrument station coordinates output (Da)
a) Data identifying code
b) lnstrurnent station N coordinate
C) lnstrurnent station E coordinate
d) lnstrurnent station Z coordinate
4. Distance and horizontal angle setting-out data output (Db)
a) Data identifying code
b) Distance setting-out data
C) Horizontal angle setting-out data
5. Backsight station coordinates output (Dd)
a) Data identifying code
b) Backsight station N coordinate
C) Backsight station
E
coordinate