23. DETAILS OF DATA INPUT I OUTPUT
@ Formats
for all input cornrnands
1. Instrument Parameter Settings input (/B)
/B O,0,0, -40, 0, 0, 0, 0,0,0,0,O [$UM] CR LF
Same format as B output command.
Prism constant input using /B is registered as a value for both prism and sheet.
2. lnstrurnent station coordinates input (/Da)
/Da 123.456, -123.456, -999.999 [,SUM] CR LF
Same format as Da output command.
3. Distance and horizontal angle setting-out data input (/Db)
/Db -123.456, 359.5959 [,SUM] CR LF
Same format as Db output command.
4. Horizontal required angle input (/DG)
Data identifying code
Required horizontal angle
5. Backsight station coordinates input (/Dd)
/Dd 123.456, -123.456, -999.999 [,SUM] CR LF
Same format as Dd output command.
6. lnstrument and target heights, temperature and pressure data input (/De)
/De 12.345, 1.500, -20, 1015 [,SUM] CR LF
a
b
c
d
e
Data identifying code
lnstrurnent height
Temperature
Pressure
7.
Coordinates setting-out data input (/Df)
/Df 123.456, -12.34, 9.182 [,SUM] CR LF
Same format as Df output command.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Set300Set6oocSet500Set6ooSet5ooc

Inhaltsverzeichnis