2 TECHNICAL SPECIFICATIONS
2.1 CPS2 12V/16A, 24V/08A, 12V/25A, 24V/12A
Model
Input
Voltage
Frequency
Current intensity 230/115VAC
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Overall
rated
current
power
Load curve
Type of batteries
Regulated and filtered output voltage
Regulation tolerance before distributor
and fuses
Peak-to-peak ripple and noise
Automotive output fuses mounted in
parallel in the BAT pole -
Environment
Operating temperature
Cooling
Relative humidity
Storage temperature
Case
Material
Paintwork
Dimensions excluding cable gland (length,
height, depth)/Weight
Fixing centre distances
Wall screw
Protection factor
Board protection
Standards
CE/CEM markings
CE/safety markings
Electrical protection
www.Busse-Yachtshop.de
CPS2/12-16
From 85 to 265VAC, single-phase
From 47 to 63Hz
1.4A/2.9A
0.9 in rated conditions
> 80% in rated conditions
2 x 6.3A/250V – Ref. DEL MICRO FUSE 00346623MST
3 separate outputs BAT D, BAT 1 and BAT 2 (integrated distributor). Each
output can be used on its own and supply the entire current.
(+/-7%)/Rated
16A/228W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption,
Floating – factory setting).
See switch settings table
See switch settings table. Chargers can operate on DC supply.
< 2%
< 250mV
1 x 20A/32V (F3) 1 x 10A/32V (F3) 1 x 25A/32V (F3) 1 x 15A/32V (F3)
-10°C to +45°C ; +45°C to +50°C with 10% de-rating of rated Power/°C
Up to 70% (95% with no condensation)
-20°C to +70°C
Case comprises 3 parts: aluminium frame and steel flap and hood
Mat black, yellow, and grey epoxy coating
269 x 179 x 106mm / 2.2Kg
247 x 110mm
4 M5 round screws
IP21
Protected with water-repellent varnish (marine environment)
NF EN6100-6-1, NF EN6100-6-2, NF EN6100-6-3, NF 6100-6-4
NF EN60950, NF EN603635-2-29
-Against leaking input surges by rupture of VDR (voltage-dependent resistor)
-Against output polarity reversals by rupture of fuses
-Against output short-circuits and surges
-Against abnormal overheating by cutting off the charger (internal
temperature probe 90°C)
-Against output surges
CPS2DEA.DOC
email: info@busse-yachtshop.de
CPS2/24-08
1.3A/2.8A
08A/228W
< 500mV
Natural dissipation
CPS2/12-25
CPS2/24-12
2A/4.2A
25A/356W
< 250mV
Draft fan controlled by internal
temperature probe 60°C +/-5°C
24
1.9A/4A
12A/342W
< 500mV