Mounting instructions (fig.
1.
Lift off the cover plate
as shown (fig. : A,B & C)
2.
Open the detector
and lower the cover (fig.
3.
Break out one or both cable entry hole(s)
4.
Mount the detector between 1.8 to 3.0 m high.
5.
Select the mounting holes for corner
6.
Use the base as a template for marking screw hole locations on the wall.
7.
Fasten the base to the wall.
8.
Strip 5 cm of the cable and pull it through the cable entry hole(s)
relief
(fig. ).
9.
Wire the detector as shown (fig.
Mounting hole for swivel bracket
Optional spare terminal
10. Close the detector hinge cover (fig.
plate
.
The detector is a microwave verified PIR intrusion detector and should be installed to
maximise PIR detection. Consequently the best detection is obtained with the ex-
pected movement of an intruder perpendicular and/or diagonal towards to the mount-
ing location.
Siting the detector (fig.
The dual technology processing of this detector is very resistant to false alarm
hazards. Nevertheless avoid potential causes of false alarms, such as:
PIR Hazards:
Direct sunlight on the detector
Heat sources within a field of view
Strong air draughts on the detector
Large animals in a field of view
Microwave Hazards:
Mounting surface susceptible to vibrations
Metal surfaces reflecting microwave energy
Water movement through plastic pipes
Heating or air-conditioning ducts pointed directly at the detector
Aritech recommends that the detector is regularly walk tested and checked at the
control panel.
DD100(c)(PI) only (PI = PET Immunity) (fig.
This detector is designed to be immune up to certain sizes of pets. Pets up to 20 kg
will usually not cause any problems in standard applications. Larger pets are accom-
modated by mounting the PI detector upside down 90 cm from the floor. The recom-
mended minimum mounting height of the PI application is 2.4 m.
DD105(c) only, dual loop feature (Jumper J1) (fig.
1: Standard Alarm Loop
The tamper output is isolated from the alarm relay output and the end-of-line resistor
in the tamper circuit is short-circuited.
Terminals 3 and 4 of the alarm relay output must be used to connect to the control
panel.
Terminal 5 cannot be used to connect an end-of-line resistor. In this case use an
optional spare terminal in the base of the detector (fig.
2: End-of-line Loop
Tamper output is isolated from the alarm relay output.
The impedance of the tamper loop is now 4K7.
Terminal 4 and 5 of the alarm output must be used for connecting to the control panel.
Impedance of the alarm relay loop is 4K7.
3: Dual Loop (fig.
)
With a Dual Loop, the tamper loop and the alarm loop can be monitored over two wires.
In figure
examples are given on how to connect the detector to the control panel
and the different positions of the jumper J1 in the different detectors (Dual Loop
single and multi devices).
In normal situation (no alarm) the Dual Loop impedance is 4K7.
In case of detector alarm, the alarm relay contact will open and the impedance of the
Dual Loop will increase to 9K4, indicating an alarm. When the detector housing is
opened, the tamper circuit will be opened and the Dual Loop interrupted, indicating a
tamper alarm.
LED function (fig.
&
)
To walk test the detector, make sure jumper J2 is in the ON position or, in the off/
remote position and the LED is enabled remotely.
LED jumper and remote control of LED (fig.
Move jumper J2 to position OFF/REMOTE. The LED is now disabled. It may be
enabled remotely by applying a 0 V potential to terminal 8.
)
).
as required.
or flat wall
mounting.
&
).
(fig.
)
), insert the screw
and replace the cover
-
)
ï
b
&
)
).
&
)
Range adjustment (fig.
PIR and microwave ranges adjusted independently by setting J3 and J4.
Always select the appropriate range setting for the dimensions of the area to be
protected area. Verify the coverage pattern and adjust as required.
Window mask (fig.
The mask is pre-fitted to the inside of the detector window and is used to mask objects
that are close to (within 1.5 m) or directly under the detector. This disables the part of
the curtains looking at an object whose closeness might otherwise cause a false
alarm.
Remove this mask to detect undercrawl.
Technical Data
and strain
Input power
Peak-to-peak ripple
Current consumption
Normal operation
Alarm
Mounting height
Target speed range
Microwave frequency
Maximum microwave
output power at 1 m.
(Continously)
Frequency stabilised
(Over temperature range)
Alarm output
Tamper output
Alarm time
Walk test
Operating temperature
Relative humidity
Size
Weight
Mirror type
DD100/DD100C/DD100PI
DD105/DD105C
Number of zones
DD100/DD100C/DD100PI
DD105/DD105C
View angle
Housing meets
(with sealed cable entry)
Dual loop
&
)
DD100/DD100C/DD100PI
DD105/DD105C
Pet immunity
DD100 Series
DD105 Series
NO restriction of use
Not to be used in:
France, Ireland, United Kingdom
- 3 -
&
)
c
)
9-15 VDC (12 Vnom.)
2 V (at 12 VDC)
11.5 mA nom.
15 mA max.
min. 1.8 - max. 3.0 m
min. 0.2 - max. 3.0 m/sec.
2450 MHz
0.005 µW/cm 2
C version only
80 mA at 30 VDC
100 mA at 30 VDC
3 sec.
0 VDC to terminal 8
-10° C to +55° C
30 to 95 %
123 x 61 x 58 mm
150 g
5C90D47
7C90D47
5 at 10.0 m
7 at 12.0 m
86°
IP30 IK02
No
Yes
DD100C / DD100PI
No
DD100 / DD100PI / DD105
DD100C / DD100CPI / D105C

Werbung

loading

Inhaltszusammenfassung für GE Interlogix DD100

  • Seite 1 Aritech recommends that the detector is regularly walk tested and checked at the DD105/DD105C 7C90D47 control panel. Number of zones ï DD100(c)(PI) only (PI = PET Immunity) (fig. & DD100/DD100C/DD100PI 5 at 10.0 m DD105/DD105C 7 at 12.0 m This detector is designed to be immune up to certain sizes of pets. Pets up to 20 kg View angle 86°...
  • Seite 2 Séries DD105 La borne 5 ne doit pas être utilisée pour la connexion de la résistance de AUCUNE restriction d'utilisation DD100 / DD100PI / DD105 boucle, dans ce cas utiliser le bornier additionnel fig. Ne pas être utilisé en: DD100C / DD100CPI / DD105C 2: Boucle d’alarme avec résistance de 4.7 kOhms : J1 retiré...
  • Seite 3 Verwarmings- of airconditioningsbuizen die recht op de detector gericht zijn Aritech adviseert om regelmatig een Looptest van de detector uit te voeren en het Gewicht 150 g resultaat op het controlepaneel te verifiëren. Type spiegel DD100(c)(PI) ALLEEN (PI = HUISDIER RESISTENT) (fig. & DD100/DD100C/DD100PI 5C90D47 DD105/DD105C 7C90D47 Deze detector is ontwikkeld om resistent te zijn voor bepaalde grootte van huisdieren.
  • Seite 4 Alarme Alarme Alarme verify J1 settings / Panel tamper/ tamper/ tamper/ verifier la Dual loop zone position A.P. A.P. A.P. de J1 DD105/DD105C #1 DD105/DD105C #2 DD105/DD105C #X © 2004 GE Interlogix BV. All rights reserved. - 1 - 4120-3D...
  • Seite 5 DD100/DD100C DD100C/DD100PI 10 m 10 m 10 m 3.0 m max. 2.4 m nom. 1.8 m min. 10 m 10 m DD105/DD105C 12 m 3.0 m max. 2.4 m min. 0.6 m 10 m 12 m 3.0 m max. 2.4 m nom.
  • Seite 6: Ausrichten Des Melders

    Dual-MG unterbrochen oder kurzgeschlossen erfolgt somit sofort eine Sabotage- Aritech VS200 (50 Siegel pro Blatt) bestellt werden. Es darf nur ein Melder aus der bedingung für die Zentrale. DD100-D Baureihe ohne Alarmspeicher an eine Meldegruppe angeschaltet werden. LED-Funktion (Abb. &...
  • Seite 7 Aritech raccomanda di sottoporre regolarmente il sensore al test di copertura ed eseguire il controllo sulla centrale di allarme. Dimensioni 123 x 61 x 58 mm Solo per DD100(C)(PI), (PI= Immune ad animali) (fig. & Peso 150 g Specchion modello Questo rilevatore è...
  • Seite 8 Doble bucle Aritech recomienda que se efectúe periódicamente un prueba de condición con el DD100/DD100C/DD100PI detector, comprobándolo al mismo tiempo en el panel de control. DD105/DD105C DD100(C)(PI) (PI=INMUNE A MASCOTAS) (fig. & Inmunidad frente a mascotas DD100 Series DD100PI / DD100CPI Este detector ha sido diseñado para ser inmune a cierto tamaño de mascotas.

Diese Anleitung auch für:

Dd100cDd100piDd105Dd105c