Herunterladen Inhalt Inhalt Diese Seite drucken

Other Faults - ergoline CLASSIC 8000 ULTRA Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für CLASSIC 8000 ULTRA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Please read and observe ...
Faults
On the control panel there are 6 displays which help you to find the cause
of various faults – see page 48. The relevant symbols flash when a fault
occurs.
The address for Customer Services is on page 2.
Symbol Cause/Action
Safety switch, hand tanner filter disk
– Check that the filter disks are securely in place.
Fault on vane switch (fan)
– Call customer service.
Safety switch, facial tanner filter disk
– Check that the filter disks are securely in place.
Hand tanner temperature control
– Call customer service.
Facial tanner top temperature control
– Call customer service.
Facial tanner bottom temperature control
– Call customer service.
38

Other faults

Cause/Action
All the symbols on the
Safety switch, disc holder or hand
control panel are flash-
tanner cover
ing
– Check that the disc frame or
hand tanner cover are correctly
closed/secured.
UV lamps and fan do
No voltage.
not switch on when the
– Check whether the fuse and the
timer or the control sys-
cut-out are switched on.
tem is activated.
The tanning device is
The device is insufficiently cooled.
overheating.
– Replace the filter element.
– Improve ventilation in the cabin..
– Call customer service.
One or more of the UV
The UV lamp is loose or it is defec-
lamps are not lighting
tive.
up.
– Insert the UV lamp correctly or
replace it
One or more of the UV
The starting device is defective.
lamps are not lighting
– Call customer service.
up.