6.2.5. Keypad protection codes
F05
F05.033 Protected group F01
F05.034 Protected group F02
F05.035 Protected group F03
F05.036 Protected group F04
F05.037 Protected group F05
F05.038 Protected group F06
F05.039 Protected group F07
F05.040 Protected group F08
F05.041 Protected group F09
F05.042 Protected group F10
F05.043 Protected group F11
F05.044 Protected group F12
F05.045 Protected group F13
6.2.6. Key commands and control input definitions
F06
F06.050 Function assignment to key „UP"
0=
No function
1=
Reset counter 1 (encoder 1) **)
2=
Reset counter 2 (encoder 2)
3=
Reset counter 1 and counter 2
4=
Set counter 1 to Set Value 1 *)
5=
Set counter 2 to Set Value 2 *)
6=
Set both counters to Set Value *)
7=
Inhibit counter 1
8=
Inhibit counter 2
9=
n.a.
10= Start serial transmission
11= Reset minimum/maximum records
12= Scroll actual display
13= Special command (depends on counter mode)
14= n.a.
F06.051 Function assignment to key „DOWN"
See key „UP"
F06.052 Function assignment to key „ENTER"
See key „UP"
*) Parameter F10.101 defines the source of the Set Value (see 6.3)
**) Clears also points of change of direction (section 4.1)
6.572.116_118_05a_e.doc / Sep-08
Range
0 = no protection
1 – 999 999 =
Protection code
for the actual
group
Range
0 ... 14
0 ... 14
0 ... 14
Page 29 / 43
Default
0
Default
0
0
0