Herunterladen Inhalt Inhalt Diese Seite drucken

Dpa 8225 - Dynacord DPA 8150 Bedienungsanleitung

Promatrix 8000 serie
Vorschau ausblenden Andere Handbücher für DPA 8150:
Inhaltsverzeichnis

Werbung

PROMATRIX 8000 POWER AMPLIFIER
11.2

DPA 8225

Specification
Rated RMS Voltage Swing, 1 kHz, THD = 1%
Load Impedance
Maximum Midband Output Power, 1 kHz, THD
= 1.5%
Rated Output Power, 1 kHz, THD < 0.5%, 2
channels driven
Max. RMS Voltage Swing, 1 kHz, THD = 0.2%,
without load
Voltage Gain, ref. 1 kHz
Input Sensitivity, rated power at rated load, 1
kHz
THD at rated output power, MBW = 80 kHz, 1
kHz
IMD-SMPTE, 60 Hz, 7 kHz, half rated output
power
DIM 30, 3.15 kHz, 15 kHz
Input Level, max.
Crosstalk, ref. 1 kHz at rated output power
Frequency Response, ref. 1 kHz, rated load
Input Impedance, active balanced
Damping Factor, 1 kHz, rated load
Slew Rate
Signal to Noise Ratio, A-weighted
Output Noise, A-weighted
CAN Port
Control Port
Output Stage Topology
Power Requirements
Power Consumption, AC and DC
Inrush Current
50 V
10 Ω
260 W
250 W
56 V
30.2 dB
+6 dBu (1.55 Vrms)
< 0.5%
< 0.8%
< 0.2%
+18 dBu (6.15 V
< -70 dB
50 Hz (-3 dB) to 20 kHz (-6 dB)
20 kΩ
> 5
14 V/µs
> 102 dB
< -62 dBu
10 to 500 kBit/s, 2 x RJ-45
1 x 8-pole connector
3 Control Inputs/Outputs (max. 60 V / 1 A)
2 Reference Outputs (15 V/100 mA and
GND/100 mA)
1 Ready/Fault Output (max. 30 V / 1 A)
Class-D, Transformer, Floating
115 V/230 V AC (-10%/+6%), 50 to 60 Hz or
24 V DC (-10%/+30%)
see table below
< 20 A
Bedienungsanleitung
Sicherheitshinweise | de
70 V
100 V
19.6 Ω
40 Ω
80 V
115 V
33.1 dB
36.2 dB
)
rms
11-Jul-13 | 03 | F01U217494
37

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dpa 8412Dpa 8225

Inhaltsverzeichnis