Herunterladen Diese Seite drucken

Bosch BMCT-AMS Bedienungsanleitung Seite 9

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
Wall switch for smart actuators
Installation and mounting instructions
݃ The standards and directives applicable in your country must be
observed during planning, set-up, operation and maintenance.
݃ The device is part of the building installation. Operation of the device is
only permitted at 230 V/50 Hz AC voltage.
Work on the 230 V network may only be carried out by an
electrician. The applicable accident prevention regulations must
be observed. To avoid an electric shock on the device, please
switch off the mains power. Failure to observe the installation
instructions may result in fire or other hazards.
݃ Mounting must be carried out following the applicable requirements.
Failure to observe the requirements may result in damage to property
and/or injury, or even danger of death.
݃ Please also note any additional information on the product.
݃ The product is only intended for fixed, indoor installation in flush-
mounted switch boxes with a minimum depth of 35 mm and a screw
distance of 60 mm.
݃ When connecting the device terminals, ensure that permitted wires and
wire cross sections are used.
݃ The power circuit to which the device and the load are connected must
be secured with a circuit breaker in accordance with EN60898-1 (trigger
characteristics B or C, max. 16 A rated current, min. 6 kA breaking
capacity, energy limitation class 3). Installation guidelines in accordance
with the applicable national standards – e.g. VDE 0100, HD384 or IEC
60364 – must be observed. The circuit breaker must be easily accessible
for the user and labelled as a disconnecter for the device.