Environmental conditions / approvals / tests
Compensated temperature range
Operating temperature range
Storage temperature range
Fluid temperature range
EMC
Vibration resistance
Shock resistance
5)
Protection type
/
conformity
approval
6)
approval
Other data
Supply voltage
when applied acc. to UL specifications
Residual ripple of supply voltage
Current consumption
Life expectancy
Weight
Smart functions
Operating data logging
(resettable as well as persistent over
the whole life cycle)
Measurement channel-related events
Communication
Note: Reverse polarity protection of the supply voltage, excess voltage, override and short circuit protection are
provided.
FS (Full Scale) = relative to complete measuring range; ;
B.F.S.L. = Best Fit Straight Line
1)
Other measuring ranges on request.
2)
Other threads on request.
Including non-linearity, hysteresis, offset and final value deviation
3)
4)
Standard up to -25 °C with FKM seal, -40 °C on request
5)
With mounted mating connector in corresponding protection type the tightening torque must not be exceeded
Environmental conditions acc. to 1.4.2 UL 61010-1; C22.2 no. 61010-1
6)
Contact
Questions relating products and documents
HYDAC ELECTRONIC GMBH
Hauptstrasse 27
D-66128 Saarbruecken
Germany
Web:
www.hydac.com
E-mail: electronic@hydac.com
Phone: +49 (0)6897 509-01
Fax.:
+49 (0)6897 509-1726
-25 .. +85 °C [-13 .. +185 °F
4)
-40 .. +100 °C / -25 .. +100 °C [ -40 .. +212 °F/ -13 .. 212 °F]
-40 .. +100 °C
4)
-40 .. +125 °C / -25 .. 125 °C [-40 .. +257 °F/ -13 .. +257 °F
EN 61000-6-1 / -2 / -3 / -4
DIN EN 60068-2-6
DIN EN 60068-2-27
DIN EN 60529
Provided
Provided
Provided
9 .. 35 V DC (18 .. 30 V DC for communication range)
- limited energy - acc. to 9.3 UL 61010; Class 2;
UL 1310/1585; LPS UL 60950
≤ 5 %
< 25 mA
> 10 million switching cycles (0 .. 100% FS)
~ 45 g
Applicable for HPT 1000S only
Pressure (min /max / average values); operating time,
i.e. general (hours counter); Arrhenius value (device
temperature, weighted operating time)
General measuring channel-related operating times
Event counter; Statistics for the actual use (operation
per measuring range segment / over/undershooting,
overload, etc.)
Via CANopen protocol or SAE J1939 protocol,
depending on version
[-40 .. +212 °F
 25 g (10 .. 500 Hz)
100 g / 6 ms / half-sine
500 g / 1 ms / half-sine
IP 67