Caution! Risk of cuts! The
adapters supplied and plunger
extensions are joined together
with plastic tabs. Snapped o
edges can be sharp.
he notches 13 ensure the adapter 14 fi ts
perfectly.
1. If required, slide the adapter 14 that fi ts the
radiator valve onto the radiator valve until the
adapter (14) snaps into place.
If necessary, use a screwdriver to slightly prise
open the adapter (14) in the area of the screw.
2. Fix the corresponding adapter (14) with the
screw and nut supplied (see Fig. B and Fig. C
on the fold-out page).
In the case of RAV valves (B), the stem exten-
sion (15) must also be mounted on the valve pin
(see Figure B on the fold-out page).
3. Use the union nut (1) to assemble the device
onto the adapter (14) or directly onto the radi-
ator valve.
4. Press the
starts automatically.
The device adapts to the radiator valve. To do this,
the radiator valve is opened and closed several
times so that the device learns the respective end
points. This process may take a few minutes.
84
G
button (6 c). The adaptation
OK