3.2.5.Components
The "Rooms" tab on the dashboard takes you to the component overview, where you will also find the "Add new
Component" button. You can use this to add your Comfion products to the system.
With a long click, you can also edit a component that has already been connected and adjust the following device
settings:
Temporary deactivation
Name
Zone number
Zone type
Zone behaviour
If a detector is programmed for the zone type output or input/output, the system only checks
the detector status after the delay time has elapsed when the system is armed.
- If the detector is not ready after the time has elapsed and "Bypass" is activated, the detector
is automatically bypassed after the delay time and the system is armed.
Note
- If the detector is not ready after the time has elapsed and "Bypass" is deactivated, the
system is not armed.
OFF (default): Component functioning normally
ON: Component is deactivated (no function)
Component naming
Assignment of the zone number (done automatically by the system)
•
-> triggers an input delay, after which an intruder alarm is triggered
Input
•
can be open during the output delay, functions like an
Output ->
immediate zone after arming
•
uses an input & output delay
Input/output ->
•
Immediate (intrusion)
armed
•
Immediate (monitored) ->
is armed; when the system is disarmed, a notification is sent when it is
triggered
•
24-hour intruder alarm
•
24-hour water alarm
•
24 hour fire
-> fire alarm independent of system status
•
-> If the zone is triggered when armed, you have the option of
Bypass
bypassing it
•
Transfer confirmation: If this item is activated, the signalling of zone
alarms is delayed by the programmed time.
-> triggers an intruder alarm when the system is
works like the immediate zone when the system
-> intruder alarm independent of system status
-> water alarm independent of system status
|13