Installation and mounting
Electricity supply
The device must be connected to an earthed socket.
Check that the socket you wish to use provides the voltage that is stated on the
type plate of the device.
The electricity supply to which the device is connected must be protected by an
earth leakage circuit breaker (max. 30 mA).
Permanent installation
The device is designed to be installed at a permanent location and connected
directly to the electricity network. The installation must be equipped with an (RC:
extra) on/off switch. For safety reasons, this installation must be carried out by a
professional electrician.
Temporary installation
As a temporary facility, the device can be directly connected to a socket via its
electric cable and plug. The device will then be switched on and off by inserting and
removing the plug from the socket (RC-version has on/off switch). Ensure that the
electric cable does not hang off sharp edges, is not twisted around sharp corners,
cannot be dragged along and does not come into contact with any hot surfaces.
Important: electrical cable and plug form one, single unit. If the electric cable or
plug becomes damaged, they must be replaced in their entirety by an electrician.
Only allow original parts to be used!
Location
The device must be installed with its lowest point at least 180 cm from the ground
(A) for both wall and ceiling installation.
The best efficiency will be obtained by placing the Outdoor heat panel horizontally
against the ceiling or roofing. If you mount the device on the wall, the efficiency
reduces by a max. 40%.
The ideal position for the Outdoor heat panel is directly above the area/persons to
be heated. The maximum output point is located directly under the Outdoor heat
panel; as the distance increases, the temperature decreases.
When installing outdoors, under a roof covering, the most effective installation
height is between 220 and 270 cm. Never hang the device higher than 320 cm
above the ground.
Ceiling installation:
Maintain a minimum distance to all side walls of 100 cm, see diagram (model may
vary!!) Also maintain a minimum of 1 metre around the device that is free from
obstacles.
Wall installation:
Maintain a minimum distance to all side walls and ceiling of 20 cm, see diagram
(model may vary!!) Also maintain a minimum of 150 cm around the device that is
free from obstacles.