. Preparing and setting up the air conditioner
 Remove all packaging material and check the air conditioner for any damage
before you put it into operation.
Warning!
Risk of fire!
The refrigeration system of the appliance contains the
natural refrigerant propane (R290).
 During operation, storage and installation, the
room should have an area of at least 4 m² in order to
ensure an adequate amount of air in case of damage
to the refrigeration system.
 Please refer to the safety instructions under
"Information on refrigerant".
 Leave the air conditioner in a vertical position for at least 24 hours before
switching on.
 Operate the air conditioner at an ambient temperature between 5°C and 35°C.
 Follow the instructions in "3.3. Product-specific hazards" on page 185.
.. Mounting the condensate drainage hose
The condensate water can be automatically channelled into a suitable container or
into a drain.
 Remove the closure from the condensate outlet.
 Connect the condensate drainage hose securely and properly and make sure it is
not kinked and is free of obstacles.
 Place the outlet of the condensate drainage hose over a drain or container and
ensure that the water can flow out of the appliance unhindered.
 Do not submerge the end of the hose in water; otherwise there may be an
'airlock' in the hose.
 To prevent water from leaking, please note that the hose must have a gradient
of at least 20%.
 Secure the hose on the drain or container to prevent uncontrolled water
outflow, as the water pressure is very strong and can move the hose.
DE
FR
NL
ES
IT
EN
SL
191