TIME SERVER CONNECTION STATUS
After the console has connected to the internet, it will attempt
to connect to the internet time server to obtain the UTC time .
Once the connection succeeds and the console's time has
been updated, the "
The time will automatically synchronize Internet time server at 12:00AM and 12:00PM per day .
Also you can press the [REFRESH ] key to get the internet time manually within 1 minute .
ADVANCE SETTING IN WEB INTERFACE
Press "ADVANCED" key at the top of web interface to enter the advance setting page, this
page allow you to set and view the calibration data of the console, as well as update the
firmware version on PC / Mac web browser.
Press "SETUP" icon to
switch to Setup page
Select setting unit
Outdoor and CH 1~7
temperature calibration
section
Pressure calibration
section
Current firmware
version
" icon will appear on the LCD .
ADVANCED page
SETTINGS
SETUP
o
Temperature
C
Indoor
Current offset: 1
Outdoor
Current offset: -9
CH 1
Current offset: 2
CH 2
Current offset: 3
CH 3
Current offset: 1 .2
CH 4
Current offset: -0 .2
CH 5
Current offset: -20 .1
CH 6
Current offset: 11 . 5
CH 7
Current offset: 0 .2
o
Range: -20 .0 ~ 20 .0
C
o
-36 .0 ~ 36 .0
F (Default: 0 .0)
Pressure
Absolute Pressure Offset:
Relative Pressure Offset:
Setting Range:
-560~ 560hpa / -16 .54 ~ 16 .54inHg / -420 ~ 420mmHg
*Rain gain:
*Wind speed gain:
*Wind direction:
*UV gain:
*Light gain:
* Depends on the model
Firmware version: 1 .00
ADVANCED
Humidity %
Current offset: -5
Current offset: 10
Current offset: -5
Current offset: -2
Current offset: -2
Current offset: -5
Current offset: -3
Current offset: -10
Current offset: -3
Range: -20 ~ 20
(Default: 0 .0)
hpa
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current gain: 0 .85
Range: 0 .5 ~ 1 .5(Default: 1 .00)
Current gain: 0 .75
Range: 0 .5 ~ 1 .5(Default: 1 .00)
o
Current offset: 2
o
Range: -10 ~ 10(Default: 0
)
Current gain: 1 .1
Range: 0 .01 ~ 10(Default: 1 .00)
Current gain: 1 .1
Range: 0 .01 ~ 10(Default: 1 .00)
Browse
Upload
16
Outdoor and CH 1~7 humidity
calibration section
Select setting unit
Current offset value is the value
that you set before to offset the
pressure reading .
The rain, wind speed, UV and Light
calibration use gain method . The
wind direction is +/- 10 offset.
The firmware update function is
only available through PC or Mac
web browser