Electrical and Electronic Equipment Waste, to
be taken to designated facilities for recycling
and disposal.
Guaranteed sound power level
1.4. STOPPING AND TURNING OFF THE ROBOT
LAWN MOWER IN SAFE CONDITIONS
OBLIGATION:
Always switch off the robot lawn mower in safe
conditions before any cleaning, transport or
maintenance operation.
1. Press the "STOP" button (Fig. 1.A) to stop the robot lawn
mower safely and open the protective cover (Fig. 1.B).
2. Press the off button (Fig. 1.E) for a few seconds and wait
for the LED on the same button to go out.
3. Only after the LED has gone out (Fig. 1.E), remove the
safety key (Fig. 1.D) to switch off the robot lawn mower
in safe conditions.
4. Close the protective cover (Fig. 1.B).
5. The robot lawn mower is stopped or switched off in a
safe condition.
2.
INSTALLATION
WARNING:
Do not modify, tamper with, elude or eliminate
the safety devices installed.
NOTE: For further clarification on the installation of the
product please contact a STIGA dealer.
INSTALLATION COMPONENTS (Fig. 3)
(A) Charging base, (B) Charging base Power Supply Unit, (C)
Satellite reference station, (D) Charging base fixing screws
(E) Separate Satellite Reference Station Installation Bracket
, (F) Separate Satellite Reference Station Installation Power
Supply (optional), (G) 5 m or 15 m extension cords, (H) Mobile
device (not included).
2.1. VERIFICATION OF THE INSTALLATION
REQUIREMENTS
2.1.1. GARDEN ASSESSMENT:
• Assess your garden for virtual perimeters, obstacles, and
areas to be excluded.
• Level the ground to prevent puddles from forming after
a rainfall.
2.1.2. CHECKS FOR THE INSTALLATION OF THE
CHARGING BASE, THE POWER SUPPLY UNIT AND
THE SATELLITE REFERENCE STATION:
ELECTRICAL HAZARD:
It is absolutely necessary to provide an
electrical outlet that complies with the relevant
laws of the country.
EN
ELECTRICAL HAZARD:
The circuit provided must be protected by
a residual current device (RCD) with an
activation current not exceeding 30 mA.
ELECTRICAL HAZARD:
Do not connect the power supply to an
electrical outlet if the plug or the cable is
damaged.
Do not connect or touch a damaged cable
before it is disconnected from the power
supply.
A damaged cable can lead to contact with
live parts.
1. Provide a flat surface at the edge of the lawn to position
the charging base. The charging base must be installed
in a location that can be reached by the satellite signal,
preferably in an area of the garden where the sky is fully
visible.
2. In the area in front of the charging base there must be
a stretch of land at least 2 m wide and at least 3 m long
without obstacles.
3. If the sky is not completely visible from the charging base
installation point, the satellite reference station must be
installed in another area
NOTE: The sky is considered fully visible when clear at
an angle of at least 120 degrees in all directions.
WARNING:
The power cable, power supply unit, extension
cord and all other electric cables which do not
belong to the product must remain outside the
cutting area to maintain their distance from
hazardous moving parts and prevent damage
to cables which may come into contact with
live parts.
4. Set up the installation area of the power supply unit in
such a way as to prevent it from being submerged by
water under all weather conditions. Preferably install in a
closed room and protected from weather conditions, in a
location not easily accessible by unauthorised persons.
2.1.3. CHECKS TO DEFINE THE VIRTUAL PERIMETERS:
1. Check that the maximum slope of the work area is less
than or equal to 45% or 50% depending on the model
(see Par. 7 TECHNICAL DATA). When defining the virtual
perimeters, observe the rules shown in Fig. 4.
WARNING:
The robot can mow surfaces with a maximum
slope of 45% or 50% depending on the model.
In case of non-compliance with the
instructions, the robot may slip and exit the
work area