8.

Problems and Troubleshooting

Before looking for problems with the dispensing equipment, first check:
Is the electricity to the device interrupted?
Is the flow of water to the device interrupted?
Are the beverage containers empty?
Is the CO
-cylinder empty?
2
Type of problem
Beverage too warm
No water expense
No water expense CO
2
CO
-volume in the
2
beverage is too low
9.

Setting of the Carbonator Pump - CR7 UTK Sodadispenser

When installing a new carbonator pump the outlet pressure of the pump must be set to 11 bar. The filling time of
the carbonator bowl is approximately 8 seconds.
Cause
Condenser dirty or
covered
Too much beverage
being dispensed
Electronic control
defective
Water feed line interrupted
Pump defective
Air in carbonator
CO
-cylinder empty
2
Valve on CO
- cylinder
2
Closed
CO
-pressure too low
2
27
CR & LOOP SODADISPENSER
Remedy
Use brush to clean con-
denser between louvers
Note out-put capacity
Call service technician
Open water tap
Call service technician
Pull relieve valve on carbonator
Change CO
-cylinder
2
Open valve
Adjust pressure