Plast Coat HP 30
ERROR CODES
The number of flashes of the red control light represents an error code. Multiple error codes can occur at the
same time and are displayed in sequence. You should therefore observe the error display until the number of
flashes repeats itself.
NUMBER OF
MEANING
FLASHES
Constant illumi-
The PC HP 30 is trying to release a
nation
stuck rotor / stator
1
Warning - overheating
2
Overheating
3
Motor overloaded
4
Overvoltage (more than 250 Volts)
5
Undervoltage (less than 85 Volts)
6 or 7
EMERGENCY STOP activated or con-
troller faulty
8
Motor overloaded
9
Pressure sensor malfunction
10
Controller overloaded
MEASURES TO ELIMINATE THE FAULT
As soon as the control light goes out, the problem has been solved.
Otherwise the relevant error code will be indicated with flashes.
Check the ventilation (e.g. ventilation slit)
Remove the cause of the overheating (e.g. blocked ventilation slit)
and allow the device to cool down for around 5 minutes
Check whether the motor / rotor is blocked. If there are no blo-
ckages and the device will not restart, contact Wagner Service.
Ensure a suitable power supply.
Ensure a suitable power supply.
Press EMERGENCY STOP and unlock it by turning it. Briefly switch
the machine to 0 and then to F. If the machine will not start, con-
tact Wagner Service.
Check whether the motor / rotor is blocked. Check the connection
cable between the motor and the controller. If the problem cannot
be resolved, contact Wagner Service.
Check the pressure sensor and the connection cable between the
pressure sensor and the controller. Replace it if necessary.
Check whether the motor / rotor is blocked. Voltage too low (du-
ring generator operation, disable the standby function). If the pro-
blem cannot be resolved, contact Wagner Service
GB
ELIMINATING FAULTS
43