Installation instructions
Caution: Never use serrated tools in
order to avoid damage. Where necessary,
always use the appropriate tools for
tightening the coupling.
– Minimum bending radius after installation.
– Without bends after installation.
– Without bend immediately after
connection.
– Without tension after installation.
– Without torsion after installation.
Product information
System
Water supply pressure
(min.)
Water supply pressure
(max.)
Flow rate boiling water
Flow rate cold water
Flow rate hot water
* The flow rate varies, depending on the water
supply pressure and the type of tap.
Water quality requirements
pH value
Tap Active boiling 3-in-1 electronic
Check the details in the "Installation and user
manual" part 2/2, page 5.
Hydraulic box
Check the details in the "Installation and user
manual" part 2/2, page 5.
100 kPa / 14.5 psi / 1 bar
500 kPa / 72.5 psi / 5 bar
2-4 l/min * 2.5 bar
5-9 l/min *
5-9 l/min *
7-9.5
Filter
Check the details in the "Installation and user
manual" part 2/2, page 5.
Filter type
Diameter
Height incl. Filter head
Filter head
Filter disposal residual waste
Decarbonization
Odors
Chlorine
Particles
Microplastics
The use of a Franke filter is mandatory to
protect the product against lime scale deposits.
It is mandatory to change the filter based on the
water hardness table.
Failure to replace your filter will invalidate your
warranty.
7
Franke Pro M
95 mm
295 mm
Bayonet / Separate part
Yes
Yes
Yes
Yes
Yes