Motor Self-protection
The system switches off after 60 minutes of S1 operation.
To reactivate the system, disconnect and reconnect the power.
Operation by means of a power drill
1. Disconnect the power supply
2. If the product cannot be operated by electrical power, the toilet and sys-
tem can be emptied by means of a power drill.
Pressure switch pipe clogged
1. Disconnect the power supply
2. Unscrew the screw of the motor cover and remove the cover
3. If the water level is above the motor flange, empty the tank by means of
the appropriate tap and the hose (supplied).
4. Unscrew the screws of the board holder.
5. Remove the pressure switch pipe.
6. Clean the rubber hose and check the opening on the tank.
Foreign body in tank
1. Disconnect the power supply
2. Unscrew the screw of the motor cover and remove the cover
3. If the water level is above the motor flange, empty the tank by means of
the appropriate tap and the hose (supplied).
4. Unscrew the side screw of the motor ring
5. Lift the motor flange to reduce the compression of the O-ring. Insert a
screwdriver into the notch underneath the supply cable and press it down.
6. Extract the complete motor unit by means of the handles (lift the unit
vertically before tilting it).
7. Check and clean the tank and impeller/grinder.
Carbon filter
1. Remove the filter cover
2. Replace the filter
The carbon filter should be replaced once a year to ensure sufficient
filter function.
Instead of using the activated carbon filter, the system can also vent
12
through a vent pipe with diameter 20.
7.
TECHNICAL DATA
Volt
Model
Hz
(V)
P1 (W)
Genix VT
50
220-240
• Supply voltage: see electrical data plate
• Maximum operating pressure: 90 kPa / 0.9 bar / 13 psi
• Grade of motor protection: IP44
• Protection rating: F
• Noise level: <70dB(A) to EN 12050-3
• Delayed line fuses (version 220-240v): indicative values (Ampere)
• Duty: S3 -50% 1min. (30 sec on; 30 sec off).
• Ambient temperature: da +5°C a +35°C
• Start and stop levels:
Start: 72 mm above bottom
Stop: 52 mm above bottom
The system pressure should not exceed 6 m head to guarantee a
sufficient drain of the connected sanitary appliances (see rapid
guide).
• Storage temperature: -10°C +40°C
• Marking:
8.
MANAGEMENT
8.1 Storage
All the pumps must be stored in a dry covered place, with possible con-
stant air humidity, free from vibrations and dust.
They are supplied in their original pack in which they must remain until the
Hmax
Amp
pump
(A)
Cos ᵠ
(m)
0.95
530
2.5
8.0
0.91
Flow
max
(m3/h)
7.8