switched on, the appliance will operate in low-power mode by default, and the display will
show the temperature.
Note
If you switch off the appliance, you will lose the temperature and timer settings selected.
Modes
Standby mode
Press the Mode button to select Standby mode. The icon shown in Figure 15 will light up. This
function allows you to keep the appliance switched on and maintain the timer setting without
it emitting heat.
Heating mode
Press the Mode button to select Heating mode. The icon shown in Figure 16 will appear on the
screen.
Temperature
-
Press the temperature button to select the desired temperature. The temperature can be
set from 5 ºC to 40 ºC.
-
Each time the appliance is switched on, the display will show the internal temperature of
the appliance.
-
You can set or stablish the temperature in the standby mode or while it is operating.
-
When the room temperature reaches the set temperature, the device will stop operating
at high power.
-
When room temperature is 2°C above the set temperature, the appliance will stop emitting
heat. The appliance will only resume heat emission when room temperature is 2°C below
the set temperature.
Timer
-
Use the Timer button to select the time you want to switch the appliance on or off at, in a
range of 1 to 24 hours.
-
To deactivate this function, press the Timer button repeatedly until the display reaches
zero.
Child lock system
To activate or deactivate this function from the control panel, press and hold the Temperature
button for 3 seconds.