Herunterladen Inhalt Inhalt Diese Seite drucken

asmodus AMIGHTY 100W Bedienungsanleitung Seite 7

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 17
interface and againwill return you to the main screen (operational mode)
Reading and adjusting resistance: Once in the system settings interface, click blue ohm RESISTANCE button. Pressing the button
will read your atomizers resistance and pressing the ADJ button will bring up the "^" and "v" adjustment buttons so you can raise or
lower your resistance. Pressing the FIRE button will confirm and return you to the main screen. NOTE: Any adjustments to resistance
will only apply while using a TC mode.
5.System Upgrade
1.Put the device into "Download Mode" by pressing the fire button 5 times in quick succession to enter the
system settings interface. Swipe the screen until you reach the blue cloud UPGRADE button. Pressing the
button will display "Upgrade?" on the screen and pressing "YES" will confirm. "Hold down the fire button" will
appear on the screen. Hold down the FIRE button until "Download Mode" appears on the screen.
2.Connect the device to a computer via a USB data cable.
3.Open the ASMODUS Upgrade Tool and click the "Connect" button. The grey indicator light on the updating
tool will turn from gray to green when the device has been successfully connected.
4.Once successfully connected, click the "File" button and select the firmware file that you want to apply to the device. NOTE: Only use
firmware files that were specifically made for your device. Applying the wrong firmware can cause your device to malfunction.
5.Once the file has been selected, click the "Upgrade" button to apply the firmware to the device.
6.After the device has been successfully updated, "Upgrade Ok" will display on the screen.
7.Reboot the device to enjoy the new update.
6. Battery handling
1. Push the negative pole of the battery into the top battery port as depicted on the battery tray and then slide the battery in.
2. To remove the battery, apply the same upwards pressure to the negative battery port and then simply pull the battery out.
Message index:
1. "HIGH ATOMIZER": This warning is displayed when the resistance of the atomizer used is too high
2."LOW ATOMIZER": This warning is displayed when the resistance of the atomizer us is too low
3."ATOMIZER REMOVE": This warning is displayed when the atomizer's resistance is removed
4."CHECK ATOMIZER": This warning is displayed when you fire the device without an atomizer successfully connected to it
5."ATOMIZER SHORT": This warning is displayed when your atomizer short circuits
6."HIGH BATTERY": This warning is displayed when the battery's voltage is too high
7."LOW BATTERY": This warning is displayed when the battery's voltage is too low
8."WORK OVERTIME": This message is displayed when the device has been fired for longer than 10 seconds and will stop the device
from firing
9."ASMODUS" logo: This image will display when the device is powered on
10."SYSTEM OFF": This message will display when the device is powered off
05

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis