18.1 Errors, meaning, causes and suggested solutions
Error display
Meaning
Mains Fail
230V AC system power supply
missing.
WAM__ PSU Fail
230V AC power supply missing in
universal module.
Batt low
No battery power supply to
system.
WAM__ Low Batt
No battery power supply to
universal module.
Low Batt Z__
No battery power supply in zone
__.
Possible causes
•
The main fuse of the transformer of the radio
alarm system is not fitted correctly or defective.
•
The connecting cable between the system and the
base plate is not inserted correctly.
•
The main power supply to the transformer of the
base plate has failed or the power cable was not
fitted correctly.
•
Defect of base plate transformer.
•
The mains power cable to the 12V supply is not
correctly connected.
•
The transformer is not supplied with power.
•
The transformer that supplies power to the
universal module is defective.
•
The system batteries are not fully charged.
•
The lead-acid battery is not yet charged.
•
No lead-acid battery was connected.
•
The battery capacity in the detector of zone __ is
almost used up.
30
Suggested solutions
•
Replace the main fuse.
•
Check the fuse is correctly fitted.
•
Check for correct installation of the system with
the base plate and plug the connecting cable into
the proper base plate socket.
•
Check that your mains power fuse is active for
the system. Is there a 230V power supply?
•
Check for correct connection between the mains
power line and the transformer clamp.
•
Contact your installer.
•
Check for correct installation of the 12V DC
connecting cable.
•
Check that the transformer is plugged in and the
red LED on the transformer is alight.
•
Contact your installer.
•
This error should disappear when the batteries
are fully charged.
•
After max. 4 hours, the batteries are charged and
this display disappears.
•
This error should disappear when the battery is
fully charged.
•
Check for correct installation of the 6V, 1.2Ah
lead-acid battery in the system.
•
Change the detector battery within 14 days.