52
3.3.9 Table of programmable functions
No. Description
00
Save or load setups
01
Max. volume
02
Volume setting with the "Vol" buttons
1 = enabled
0 = disabled
03
Max. limit for "Voice" mode
04
Max. limit for "Free" mode
05
Max. limit for "Request" mode
06
Separate "Voice" threshold for MCS 223 (applies, when function 07 is set to
1, otherwise the general "Voice" threshold applies. Refer also to function 08.)
07
Separate "Voice" threshold for MCS 223 activated (refer to function 06)
0 = no separate
1 = separate
08
MCS 223 "Voice activation"
0 = only in the "Voice" mode
1 = in all operating modes
2 = never (when "2" is selected, the microphone is only activated via the
microphone button)
09
no function (must be set to "0")
10
MCS 223 "Priority" is linked with the microphone button:
0 = not linked
1 = linked ("Priority" function is also released via the microphone button)
11
MCS 223 "Priority" button:
0 = push button mode
1 = latching mode
2 = Auto-OFF (Auto-Off depends on the general or separate "Voice"
threshold; function 06)
12
MCS 223 Microphone button:
0 = push button mode
1 = latching mode
2 = Auto-OFF (Auto-Off depends on the general or separate "Voice"
threshold; function 06)
13
MCS 223 "Clear" button:
0 = short press: turn off activated microphone units;
long press: turn off activated and registered microphone units
1 = turn off activated and registered microphone units always; independing on
how long the button is pressed
MCS 20 – MCS 223 Microphone Unit
Value
Factory
range
setting
1 ... 7
-
0 ... 32
32
0 or 1
1
0 ... 8
8
0 ... 8
8
0 ... 8
8
1 ... 84
40
0 or 1
0
0 ... 2
0
0
0 or 1
0
0 ... 2
0
0 ... 2
1
0 or 1
0