MCW-D 50 – Setting up
4.5

How to record the Meeting

Rear view MCW-D 521 / MCW-D 523
Lateral view MCW-D 531 / MCW-D 533
14
4.6

Maintenance of the MCW-D Microphone Units

• For cleaning the MCW-D microphone units when they are slightly dirty (finger prints, dust, jam or juice) use a soft, damp cloth, sponge
or brush and a liquid cleaning agent.
• Before cleaning the surface it must be moistened thoroughly. Afterwards it must be cleaned with a damp cloth.
• Make sure not to allow any water to enter the unit.
• For dirt caused by mineral oils and fats, animal and vegetable fats use spirit, isopropyl alcohol or benzine.
• For dirt caused by ballpoint pens, typewriter ribbons or carbon paper use isopropyl alcohol or spirit.
• Clean the charging contacts of the microphone units with spirit or isopropyl alcohol from time to time.
• Clean the supplied pop shield with clear water. Make sure that it is completely dry before you put it on the microphone again.
5.

Programmable Functions of the Microphone Units with the MCW-D 50 Conference Software

The functions of the microphone units described in the following are only available, when they have been programmed with the
MCW-D 50 Conference software before. Please refer to the MCW-D 50 Conference Software manual.
5.1

Safety Code

By using the MCW-D 50 Conference software an alphanumerical code can be entered for the MCW-D microphone units and the
MCW-D 50 control unit within one system. This will increase the safety against unauthorised listening. Microphone units which do not
have this code are not recognised by the control unit and will be deactivated.
• For recording the meeting you can connect a recorder (e.g. a laptop with the
steno-s Conference and Recording software) to the documentation output
or
.
14
• The volume can be adjusted with a PC using the MCW-D 50 Conference
software.
• Instead of a recorder it is also possible to connect a headphone to the
documentation output
4
Although a lower impedance does not damage the microphone unit, the head-
phone operation, however, can be disturbed.
. We recommend an impedance of 600 Ω.
or
4
14