CALLING IN THE AUTHORISED TECHNICAL SERVICE CENTRE
If the symbol
appears on the display together with the symbol
Before calling, note down the fault code/s and the short message accompanying the fault.
If a fault code is displayed that is not included in the list or if a certain fault occurs frequently, contact the AUTHORISED
TECHNICAL SERVICE CENTRE.

FAULTS TABLE

Description of fault
10
External probe sensor
20
NTC flow sensor
28
NTC fumes sensor
40
NTC return sensor
NTC DHW sensor
50
(only for heating-only model with storage boiler)
52
Solar DHW sensor (if connected to a solar plant)
73
Solar manifold sensor (if connected to a solar plant)
Communication problem between boiler board and control unit.
83
Probable short circuit on wiring.
Address conflict between control units
84
(internal fault)
98
Accessory not detected or recognized (*)
109
Air in boiler circuit (temporary fault)
Safety thermostat tripped due to overtemperature.
110
(pump blocked or air in heating circuit)
111
Safety thermostat tripped due to overtemperature.
117
Pressure in hydraulic circuit too high
118
Pressure in hydraulic circuit too low
(*)
After powering up the boiler (or after a Reset for lockout), the error appears on the display once the self-check is completed. The fault code
is displayed permanently if the accessory is not recognized.

8. FILLING THE SYSTEM

Regularly check that the pressure displayed on the pressure gauge B is 1 - 1.5 bar, with the
boiler cold. If the pressure is too low, turn tap " A" to fill the boiler (figure to side). Open the
tap very slowly in order to vent the air.
A
Boiler/system filling tap
B
Pressure gauge
Take special care when filling the heating system. In particular, open any thermostat
valves in the system, ensure the water enters slowly in order to prevent the formation
of air inside the primary circuit until operating pressure is reached. Lastly, vent any
radiators in the system. BAXI declines all liability for damage deriving from the presence of
air bubbles in the primary exchanger due to the incorrect or imprecise observance of the
above.
The boiler is fitted with a hydraulic pressure gauge which prevents the boiler from
working if there is no water.
If pressure drops occur frequently, have the boiler checked by the AUTHORISED TECHNICAL SERVICE CENTRE.
7219836.01 (1-04/15)
, contact the AUTHORISED TECHNICAL SERVICE CENTRE.
Description of fault
No circulation safety trip
125
(control performed via a temperature sensor)
128
No flame
130
Fumes NTC tripped due to overtemperature
133
Ignition failure (4 attempts)
151
Boiler board internal fault
152
Generic parameter setting error
153
Hardware reset button pressed more than 10 seconds
160
Fan fault
321
NTC domestic hot water sensor faulty
Generic parameter setting error of solar plant
343
(if connected to a solar plant)
384
Abnormal light (parasite flame – internal fault)
385
Input voltage too low
386
Fan speed threshold not reached
No circulation safety trip
430
(control performed via a pressure sensor)
No functional earth or safety thermostat tripped due to over
432
temperature (E110)
40
bis

Quicklinks ausblenden:

Werbung