2.4 TEMPERATURE ADJUSTMENT

To adjust the temperature, turn knob B to the right
to increase and to the left
to decrease than
B to confirm.
CENTRAL HEATING
The temperature to adjust can be:
• Flow temperature: if the Control Panel is installed on the boiler.
• Ambient temperature: if the Control Panel is installed on the wall.
DOMESTC HOT WATER
B to
To adjust the Domestic Hot Water setpoint, select the "Hot water temp setpoint" function as described in section 3 and
set the request temperature value.
3.
FUNCTIONS ASSOCIATED WITH THE EASY MENU BUTTON (rapid menu
)
A and
B to scroll the following functions:
Press
• Standby/operation
• Hot water boost
• Central heating mode CH1
• Room temperature CH1
• Hot water mode
• Hot water temp setpoint
B to enable the selected function,
B to adjust the value and
B to confirm.
then
Standby/operation
If this function is enabled,
appears on the display and boiler operation is disabled in the DHW and heating modes (the anti-
freeze function remains enabled). To recover boiler operation, repeat the procedure described above.
Hot water boost
This function is used to heat the storage boiler, if fitted, until the set temperature is reached, regardless of the set time band.
Central heating mode CH1
This menu is used to select the boiler operating mode as indicated in section 4.
Room temperature CH1
Select this menu to change the comfort ambient temperature value.
Hot water mode
Select this menu to enable "On" or disable "Off" DHW. The "Eco" function is not used on this model of boiler.
Hot water temp setpoint
Select this menu to change the maximum DHW temperature value.
When DHW is disabled,
disappears from the display.

4. OPERATING MODES

4.1 HEATING

The boiler can operate in 4 different ways in the heating mode: On - Reduced - Timed - Off. To set one of the operating modes,
proceed as follows:
• From the main menu
A
B
Central heating mode CH1
B to confirm.
B (anti-clockwise)
On - Reduced - Timed - Off
B to confirm or
C to exit without saving.
CASE 1 : the Control Panel is installed in the boiler
Turn knob B to adjust the boiler flow temperature.
DESCRIPTION OF OPERATING MODES
• On: heating is always enabled (symbols displayed
).
• Reduced: heating is always disabled (symbols displayed
);
• Timed: heating depends on the set time band (symbols displayed
);
• Off: heating is disabled.