Herunterladen Inhalt Inhalt Diese Seite drucken

Auto Quit; Free Resolution (In 1/100Mm); Speed Format - TR-Electronic LE-200 Benutzerhandbuch

Vorschau ausblenden Andere Handbücher für LE-200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7.2.3.5 Auto quit

The parameter Auto quit determines whether occurring error messages should be
cleared automatically after eliminating the trouble.
Unsigned8
Byte
Bit
Data
Default (dec.)
Value Assignment
0
1

7.2.3.6 Free resolution (in 1/100mm)

The parameter Free resolution defines the measuring system resolution, if under
parameter Resolution the option free resolution (in 1/100mm) was
selected.
Unsigned16
Byte
Bit
Data
Default (dec.)

7.2.3.7 Speed format

The parameter Speed format defines the format or resolution for the speed output.
Unsigned8
Byte
Bit
Data
Default (dec.)
Value Assignment
0
1
Printed in the Federal Republic of Germany
06/07/2019
X+7
7 – 0
7
0
– 2
2
0
Description
An occurring error message can be cleared only via the
external switching input. For the switching input the function
not automatic
Failure-quit must be selected, see page 96.
An occurring error message is cleared automatically after
automatic
remedying of the error.
X+8
15 – 8
15
8
– 2
2
0
X+10
7 – 0
7
0
– 2
2
0
Description
10 mm/s
corresponds 0.01 m/s
1 mm/s
corresponds 0.001 m/s
TR - ELE - BA - DGB - 0023 - 09
X+9
7 – 0
7
0
– 2
2
100 (1 Digit = 1 mm)
 TR-Electronic GmbH 2012, All Rights Reserved
Page 95 of 111

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis