Miele PDR 516 SL G Installationsplan Seite 43

Gewerblicher trockner gasbeheizt

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Possible voltage variants
1N AC 230 V, 50/60 Hz
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Circuit breaker trip characteristic
Minimum cross-section for connection cable
Gas connection
Heater rating
Machine connection on machine side to ISO 7-1
The gas machine must be connected using a corrugated metal hose assembly made from stainless steel in
accordance with DIN 3384. The shut-off equipment must be supplied by the customer on site. The use of a
gas socket is not permitted at the specified heater rating as the flow rate is too low.
On-site threaded union for natural gas (internal thread)
On-site threaded union for liquid gas (internal thread)
Alternative connection for liquid gas with precision steel tube to DIN 2391/2393, with smooth end
Minimum connection length
Connection pressure as per DIN EN 437. Connection to gas supply must comply with national regulations.
Exhaust air/exhaust gas
Maximum nominal volume flow rate
Maximum permitted pressure loss
Connector on machine side (external diameter)
Maximum exhaust air/exhaust gas temperature
This tumble dryer is a gas fuel-burning installation without flow safeguarding equipment with a fan behind the heat exchanger (type:
B22). The exhaust air/exhaust gas line must be leak-tight. The gas connection must be carried out according to the national and local
regulations and – depending on the national codes – is subject to approval or acceptance.
As relative humidity inside the exhaust ducting can be as high as 100 %, suitable measures must be taken to prevent a backflow of
condensate into the machine.
Air intake
Standard connection: air intake from installation site
There must be sufficient air intake to the installation site to match the air outlet volume.
Alternative connection: air intake directly from outdoors
Connection sleeve on machine side (internal diameter)
Removing the protective cover exposes live parts. For safety reasons, a pipe must be installed from the tumble dryer's central fresh air
intake (over a minimum length of 900 mm) and secured with 2 screws.
Machine data
Machine width, total
Machine height, total
Machine depth, total
Niche width
Recommended wall spacing
en - Technical data
Standard connection
1N AC 230 V
50/60 Hz
0,6 kW
1×10 A
Type B
1,5 mm²
18 kW
½"
½"
½"
DN 12
40 mm
890 m³/h
300 Pa
150 mm
80 °C
161 mm
711 mm
1800 mm
1089 mm
1050 mm
1500 mm
43