Herunterladen Inhalt Inhalt Diese Seite drucken

Stel MAX 403 NAVY Betriebsanleitung Seite 13

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

again.
DEACTIVATE V.R.D.
1) Switch on the welding machine.
2) Hold down button 4 on the front panel of the
machine for about 4 seconds, then release the
button; the welding enable led 2 remains lit with a
fixed light (V.R.D. FUNCTION deactivated). VRD
mode remains deactivated when switching the
machine off and on again.
- CC/CV (SUITCASE FEEDER)
With this function the MAX 403/403S is able to
connect and then operate together with any
suitcase feeder. Please select CV Mode on the
front panel.
FAULTY
- PF0
1) Under normal conditions the MAX 403S displays
PF0 at start up on the 'A' LED. The PFC system is
now recognizing the input voltage. This process
takes approximately 3/4 sec. from start up.
2) In the event PF0 remains permantly on or is
flashing PF0, this is a result of the PFC system
being blocked..
Return for repair or have a qualified service
technician repair as per service manual.
- COn
1) The 'A' LED displays COn:
The communication between the power source and
the accessory being used is interrupted.
- If the 'A' LED continues to display COn return for
repair or have a qualified service technician repair
as per service manual.
- If in the 'A' LED continues to display Con, then
please check all connections to the power source
are securely connected and are not damaged.
Check tha all accessories to the work piece from
the power source, especially including earthing,
are secure and not damaged.
DUTY CYCLE AND
EXCESSIVE TEMPERATURE
The Led indicator light 3 is ON, and the 'A' LED
displays HT(1,3,5,7)