OPERATION WITH A CONNECTED HOB

Making the connection between cooker hood and hob

The connection to an AutoAir hob is not active by default. First the connection to the hob must
be activated.
At the same time, a setting must also be made on the hob; see the hob manual for this.
Check our website for the full range of hobs that can be connected to your cooker hood.
Making a connection
1. Turn off the hood and the lighting.
2. Press and hold the lighting button on the hood for three seconds.
The indicator lights on the on/off button and speed button 2 of the cooker hood will
flash simultaneously for a maximum of two minutes.
3. Now, on your hob, activate the pairing mode in the user menu. Select the mode U9-1
(U9-0 = no connection and U9-1 = connection with extractor hood).
The connection is successful when the indicator lights on the on/off button and speed
button 2 of the cooker hood are illuminated continuously for two seconds.
The extractor hood can now be operated via the hob.
4. Press and hold the timer button and bluetooth button on the remote control
simultaneously for four seconds.
The red LED signal flashes four times.
The extractor hood can now be operated via the hob and the remote control.
If the indicator lights on the on/off button and speed button 2 of the cooker hood are no
longer illuminated within two minutes, the connection was not successful. Repeat the
procedure. If necessary, clear the hood's memory (see below: "Disconnecting").
Disconnecting
1. Turn off the hood and the lighting.
2. Press and hold the on/off button of the cooker hood for three seconds.
The indicator lights on the on/off button and speed button 2 of the cooker hood will
flash five times simultaneously.
The hob is now no longer connected to the hood.