English
9
Disassembly and disposal
9
Disassembly and disposal
9.1
Taking the warewasher out of operation for long production stops
If the warewasher is taken out of operation for long periods (company holidays, seasonal operation), carry out the following steps:
Ø
Have the dosing devices rinsed with water by a service technician and allow them to dry. If necessary, observe the dosing device
information provided by third-party manufacturers.
Ø
Use the self-cleaning programme to empty the warewasher.
Ø
Clean the warewasher.
Ø
Open the door.
Ø
For AE RO warewashers: If the period of disuse lasts longer than 28 days, have the membranes of the reverse osmosis module
preserved by a service technician. Note: The maximum preservation time for the membranes of the reverse osmosis module
is 9 months, after which time the preservation must be renewed. In a preserved state, the warewasher can be stored at tem-
peratures as low as -10 °C.
Ø
Switch off the local water supply.
Ø
Disconnect the warewasher from the electrical mains supply.
Ø
Empty the water treatment unit (e.g. partial demineralisation cartridges).
Ø
Instruct an authorised service technician to secure the warewasher against frost.
9.2
Disassembly
Ø
Remove any wash items and baskets from the warewasher.
Ø
Empty the warewasher completely.
Ø
Disconnect the warewasher from the electrical mains supply.
Ø
Disconnect the warewasher from the local water supply.
9.3
Disposal
Incorrect or negligent disposal can cause considerable environmental pollution and/or damage.
Ø
For hazardous substances, please observe the disposal regulations on the safety data sheets.
Ø
Disposal according to national regulations.
74
|
|
11208020/04; 2023-07