Herunterladen Inhalt Inhalt Diese Seite drucken

I Optional Kits Connections; I Titanium Condenser - Zodiac DF2 Montage- Und Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 81
X2.6 - X2.7 - Filtration pump
• This connection is only used in appliances that include the titanium condenser.
• This is where the filtration pump timer clock is to be connected in parallel.
• This way when the appliance requests water flow to the filtration pump it can deliver without disturbing the timer
schedule.
X2.1 - X2.2 - Hot water coil kit
• This connection is only used in appliances that include the hot water coil condenser kit.
• This is an output signal (230 VAC, 50 Hz, 8 A maximum) sent when the appliance has to heat the air.
• Check Hot water coil kit manual for further reference.
X2.4 - X2.5 - Alarm status
• This connection is only used if the user wants to wire an external signal so that any alarm can be noticed easier.
• This is an output signal (230 VAC, 50 Hz, 16 A maximum) triggered when the appliance presents an alarm.
• The external signal is up to the user, it can be a luminous signal, a sound signal, etc...
X9.1 - X9.2 - Remote ON/OFF
• This connection is only used if the user wants to wire a remote ON/OFF switch.
• This is an input signal, DRY CONTACT. Factory setting is contact closed, meaning that no remote control is exerted on
the appliance.
X9.5 - X9.6 - Pool cover
• This connection is only used if the user wants to wire as an input signal the status of the pool cover.
• This is an input signal, DRY CONTACT. Factory setting is contact open, meaning that the pool cover is open.
Remote ON/OFF and Pool cover connection must be dry contacts:
• Failure to respect this will damage the electronics of the appliance, and will not be covered
under warranty.

2.7 I Optional kits connections

Optional kits assembly and activation :
• Refer to the installation and use manual supplied with the optional kit.
2.7.1 "Hot water coil" kit
• This option allows the dehumidifier to be used to heat the air in the room in which it is installed. A primary hot
reservoir (exchanger, boiler, geothermal heat...) has to be mounted upstream. To do so, use the "hot water coil" kit
available as an accessory.
• For the connection, consult the manual supplied with the kit.
2.7.2 "Electric heater" kit
• This option allows the dehumidifier to be used to heat the air in the room in which it is installed. To do so, use the
"Electric heater" kit available as an accessory.
• For the connection, consult the manual supplied with the kit.
2.7.3 "Fresh air intake" kit
• This option enables the appliance's to have an aditional external air inlet, mixing this external air with the air
coming from the pool installation to be dehumidified.
• For the connection, consult the manual supplied with the kit.

2.8 I Titanium condenser

• Connect the water inlet and outlet to the
appliance following the stickers indications
located next to the titanium condenrser PVC
fittings.
• Use a bypass for the water condenser, as
shown in the image.
18
Half opened valve.
Completely opened valve.
Completely opened valve.
Titanium condenser fittings.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis