INTERNAL MEMORY
changed using the arrow buttons or the "Select Wheel". When you select a new memory,
the screen displays the previously saved data, such as charge current, capacity, cell count
etc. The memory can also be selected from the working display: this is accomplished by
pressing the "ENTER" button and selecting the memory number.
SETTING THE BATTERY TYPE
possible to select the function "L3.9V": this function adjusts the battery voltage to the cor-
rect storage value of 3.9 V / cell; this is ideal for storing the battery for a protracted period.
A further press on the "ENTER" button adopts the selected battery type.
SETTING THE CELL COUNT
"ENTER" button in order to adopt the selected value.
SETTING THE BATTERY CAPACITY
SETTING THE CHARGE CURRENT
charge current in accordance with the specified charge power.
SETTING THE DISCHARGE CURRENT
Operating Instructions
Power Peak ® C8 EQ-BID
This menu can be used to set up a maximum of five
different battery types with their corresponding para-
meters; the data you enter is retained when the char-
ger is switched off. The number flashes, and can be
Pressing the "ENTER" button selects the Battery
Type parameter. Now use the "+" or "-" buttons or the
"SELECT WHEEL" to set the desired type. If you wish
to prepare a LiIo or LiPo battery ready for storage, it is
The next essential step is to select the parame-
ter "BATTERY CELLS". The appropriate cell count
can also be set at this point, as described previ-
ously. When the count is correct, you must press the
When you press the "ENTER" button, the set para-
meter flashes; at this stage you can select the battery
capacity. Press the "ENTER" button once more after
making your selection.
This parameter is used to set the charge current.
Please note that the maximum charge current varies
according to the cell count and the battery voltage.
The charger's integral processor limits the maximum
This parameter is used to set the discharge current.
Please note that the maximum discharge current
varies according to the cell count and the battery vol-
tage. The charger's integral processor limits the maxi-
mum discharge current.